does Allegion make sliding door frames

RELATED FAQS

Question
Answer
On May 1, 2013 the LM9000 lock was discontinued and replaced with the LM9300 Multipoint Lock. 
The LM9000 mortise lock, door with pre-assembled vertical rods, and frame all ship separately.  The soffit latch, bottom strike, and latch release will ship with the mortise lock, not the...
It is always recommended to point installers to the industry installation manuals which are very comprehensive and are ANSI documents. SDI (Steel Door Institute) installation manual can be found...
 Pneumatic Automatic Operators are used in areas where electrically operated devices are not convenient or permitted.  Consists of a modified, heavy-duty door closer for manual oper...
The backset for a 98/99 rim PANIC device with 1609 strike is 2 3/8" from center of the opening to center line of the device. See template
The backset is 2 3/4" from edge of door to the center line of the device and strike. The preparation for the WS98/99 strike must be specified when placing order for the frame.
Tornado shelter applications require the use of Paladin PW14-Series doors and FP14-Series frames: Tornado shelter doors are a tested system comprising of the door, frame and hardware. ...
POCKET DOOR FRAME: A frame designed to allow a door to slide inside a pocket located within the cavity of a wall. The hinge jamb of the frame is replaced with a 2 piece jamb without a stop. I...
EL98/99-4 ft rim device required minimum of 35.2" with 5/8" stop height door opening on single door and 35.56" with 4954/9954 mullion.
EPT installation guidelines are as follows: Recommended location is 6" below top hinge per template Steelcraft will locate the power transfer prep at the Von Duprin recommended template locati...
Yes, Steelcraft does offer optional A60 and A40 Galvannealed, and G90 Galvanized steel on doors and frames. Galvannealed A60 and A40: A60 coating designation - optional on all doors and frame...
Hinge backset is the dimension from the leading edge of the hinge to either the stop on the frame or to the stop face (push side) of the door. For operating clearance, the hinge backset on the d...
LCN does not does not have or supply any information for the old (obsolete) "High Energy" Dor-O-Matic Sliding doors, Bi-Fold doors or Astro Swing doors. You MUST be AAADM certified to work on, or g...
GrainTech® is a Steelcraft door option which provides a wood grained pattern which is embossed into both face sheets of the door. GrainTech doors are factory stained and top coated with a cle...
The following hinges are available on Paladin series doors and frames: Butt hinges -  4 1/2", 5" or 6" ball bearing type either standard or heavy duty Continuous hinges - full mortise...
Steelcraft locates all butt hinges from the top of the door to the centerline of each hinge as standard practice: Locating hinges to the center line of the hinge keeps all hinge locations the sa...
Electro-hydraulic Automatic Operators are: Designed for manual opening applications where there is occasional need for automating the door to meet ADA requirements.  Electrically powere...
To determine Actual Door Size, the following values are subtracted from nominal door size (frame opening/order size) Actual Door Size: The largest measured width by height of the door leaf as m...
LCN does not offer any products for sliding doors.
Lead lined frames are intended for use in the X-ray Room locations in Health Care facilities. Frames are provided by Steelcraft prepped as follows:  Frames are supplied knock-down (KD). Fram...
Electrical hinges or a power transfer units are the most commonly used practices to run electric power to locks and/or strikes. Electric Hinges: Most electric hinges will fit into a standard 4 ...
Steelcraft frames and doors are furnished with a high grade, low gloss, baked-on prime paint that provides the best possible protection against corrosion, abrasion and weather, and is an excellent ...
For both DW and K-Series Drywall Slip-on frames, Steelcraft locates the compression anchor in the jamb soffits approximately 4" down from the head on each jamb. Regardless of door opening height: ...
Yes, stainless steel doors and frames are available. Door Construction: LS-Series: Visible edge seams Door construction similar to the L-Series LSW-Series: Seamless with we...
FBC Approvals: Yes, Steelcraft doors do meet the Florida Building Code (FBC) Protocols (TAS 201, TAS 202 & TAS 203) Missile impact & ASTM E-330 applications Dade County NOAs: Yes,...
On May 1, 2013 the LM9000 lock was discontinued and replaced with the LM9300 Multipoint Lock. 
The Schlage LM9000 series lock was originally designed for use in FEMA (tornado) storm shelter openings and/or Florida Building code (hurricane) assemblies.  Doors, frames and hardware can be order...
  Specify either an L or B doors for use with the LM9000 or LMV9000 Specify the F frame for use with the LM9000 or LMV9000 Order the lock from Schlage as you would normally The concealed rods...
CAD drawings are available for doors and frames in 3 drawing formats: Autocad (.dwg) - Release 12 Encapsulated PostScript (.eps) Data Exchange (.dxf) Drawings are available on the...
During the construction cycle, spot rust is usually attributed to either material handling damage or improper storage of the material on the jobsite. The material must be repaired and repainted as ...
A simple field test can determine if a door or frame is galvanized or cold rolled steel, however this test will not determine if the steel is A60, A40 or G90. The Tech Tip can be viewed here.
Steelcraft offer a limited warranty to customers that products will be free from defects in the material and workmanship for a period of 12 months from date of shipment of products.Warranty St...
Job Specific Warranty - If job specific warranty letters or certificates are required, please refer to the Allegion Contact Us web page and request the applicable information.NOTES:F...
LCN "does not" recommend the use of SRT screws is wood doors. LCN "only" recommends the use of Wood Screws in wood doors and frames, as noted on the installation instructions.
Steelcraft Paladin PW-Series doors and FP-Series frames meet FEMA Tornado Resistant requirements and have been designed and tested to meet the requirements of FEMA 361 guidelines and ANSI ICC500. ...
ElectroMechanical Automatic Operators are designed to automatically open when activated. The Benchmark Series are Medium Duty "Commercial" automatic operators, often used on of...
Fire labels (UL, ITS/WHI or FM) are located as follows: Butt Hinges and Pivots: On the doors the fire label is located on the hinge edge between the top and 2nd hinge preparation. On the fram...
Levels and Models (covered in ANSI A250.8 (SDI 100) "Recommended Specifications for Standard Steel Doors and Frames") are SDI term aid in the selection and specification pr...
Astragals are required on: 3 hour fire rated pairs: Double doors - swinging in the same direction Double Egress - swinging in opposite directions Fire rated Dutch Doors Fire rated 1 3/4" t...
The 4040SE is non handed and can be mounted on the push or pull side of the door.
Hinge Spacing: All 4 1/2" and 5" butt hinge spacing 1. Opening heights 3'0" through 4'11 15/16" (one pair butt hinges) from under head CL 9 3/4" (top of door 9 5/8") from bottom of frame ...
Hinge Backset: On the frame = 5/16" On the door = 1/4"
Lock Spacing: All standard bored locks ANSI 115.2 (161, 61L type), for mortise lock ANSI 115.1 (86 type) all locations must be altered 3/8" lower, and standard strike (ASA type). 1. Opening ...
From head to centerline of each hinge (4 1/2" or 5") is 9 3/4", 39 3/64", 68 11/32" & 97 41/64".
The hinge spacing on a 9'0" frame opening height is 29 19/64".
From Head to top of each 4 1/2" hinge is 7 1/2", 36 51/64", 66 3/32" & 95 25/64". From Head to top of each 5" hinge is 7 1/4", 36 35/64", 65 27/32" & 95 9/64".
The three most common steel types are cold rolled steel, galvannealed steel, and galvanized steel. Cold Rolled Steel (CRS) is suitable for most interior applications, is uncoated steel a...
If the door hits the frame (or rubs on the rabbet of the head or jamb) the frame is out of square and improperly installed. Door edge rubbing on the rabbet - shimming the hinges may resolve the...
Yes, wood doors can be used and installed in most hollow metal frame applications including FE-Series and DE-Series Double Egress frames. Caution - For fire rated applications the wood door manufa...
Minimum door opening for a 98/99 rim device with a 4954 mullion and 299 strike is  26.687" (26 11/16")
Overhead Concealed door closers are used to provide a more aesthetic look to the opening.  Concealed in either the frame or the door Offer the ability to be adjusted to maintain control o...
Yes, Steelcraft doors and/or frames are available and can carry a UL, WH or FM label. The type of fire label (UL, WH or FM) is dictated by the specifications and local building code. Doors ...
The following application information apply to the 5100 electric strike: Can only be used on a single door with a cylindrical lock Can not be used on a pair of doors Can not be used on a mullion
All Steelcraft Frame, Door and Architectural Stick components will receive one coat of sprayed-on factory paint which is a baked-on, rust-inhibited primer that conforms to the industry standard ANS...
Raceway availability: Optional factory installed raceways are available in doors but are not available in frames. Preparation Info: Steelcraft installs a flexible 1/2" ID steel conduit through the...
One stabilizer set takes care of the pair of doors for one mullion.
Reveal is the distance or measurement from the face of the door out to the face of the frame on the push side of the door.Other related terms:Door face - The exposed surface of door visible wh...
Steelcraft have tested different types of doors and frame assemblies using Zero International gasket seals for the various STC ratings. Tests are in accordance to ASTM...
Frames can be installed either KD (knock down) or welded to receive the STC rating.
Steelcraft borrowed light frames are not listed/tested. Check with the glass manufacture if they are listed and with what type of framing used.
Sound seals are required. Zero International Gasket Notes: Perimeter Seals – Zero #475 applies to the stop of the head and jambs. Door bottom – Zero #367, surface applied. Threshold ...
Yes, as an option, Steelcraft doors are available with factory prepared for the 98/9949 Concealed Vertical Cable Exit Device. L, B, CE, T and CE-Series doors are available factory prepared Door...
When rust appears, repair the affected surfaces by finish smooth, clean, treat for maximum paint adhesion, and touch up the surfaces with a direct to metal (DTM), rust inhibitive primer.
Prime or painted surfaces which have been scratched or otherwise marred during installation (including field welding) and/or cleaning must be field repaired and re-primed by the installing contractor.
FastTrack is a quick ship stock program which includes targeted Builders Hardware SKUs offered by Allegion Distributor Partners. FastTrack order forms and supporting information is available only t...
Allegion Employees can access the distributors’ “My Allegion Portal” thru The Frontline Home Page: Click on “My Allegion Distributor Portal” located in the navigation menu on the left si...
CAUTION must be used in investigating this problem - In most cases, excessive field rusting of products is caused by improper storage at the jobsite. That situation must be validated prior to refus...