Do you have operations and maintenance manuals on door closers
”
RELATED FAQS
Question
Answer
Can you manually pull a 4040SE out of hold open?
Resolution:
The holding force on an SE/ME Series door closer is approximately 35 lbs. and they can be manually pulled out of hold open with approximately 35 lbs of force. :
Can the fluid in an LCN door closer be filled out in the field?
Resolution:
The fluid in an LCN closer must not be refilled in the field. See attached Warranty and Repair Communication :
What special template (ST) is used with the 2030 closer and a low profile track and roller?
Resolution:
The 2030 closer requires a minimum 1-3/8" top rail on the door for the standard track. For a top rail less than 1-3/8" and as narrow as 1", you could use the l...:
Can the 4630/4640 cylinder only be replaced?
Resolution:
The 4040(XP) door closer can be used as a temporary replacement in a 4630/4640 operator to provide manual control of the door while the 4630/4640 closer cylinder is being repaired or a replacement ...:
Can you order a 1461 cylinder only?
Resolution:
The part number is: 1461-3071 for the door closer cylinder body.:
What is the part number for the Von Duprin maintenance kit?
Resolution:
Von Duprin has a maintenance kit part number 050046-00 and maintenance instruction, part number 941079-00 for 98/99 series devices. There are some common parts between 98/99 series and 22...:
What are the dimensions of the SC70 footprint
Resolution:
The measurements from center line to centerline of the mounting holes are 2-3/8" x 6-3/4".:
What maintenance is required for an LCN closer?
Resolution:
Closers mounted according to LCN installation instructions require no periodic maintenance or seasonal adjustments. Monthly, quarterly, and annual visual inspections are recommended for Fire/...:
Can I use a Glynn Johnson 410 with a 4040 regular (pull side) mount?
Resolution:
ST-1630 is required when mounting a 4041 or 4040XP door closer regular (pull/hinge) side with a concealed GJ100 or GJ410 series over head stop.:
What are Pneumatic Automatic Operators?
Resolution:
Pneumatic Automatic Operators are used in areas where electrically operated devices are not convenient or permitted. Consists of a modified, heavy-duty door closer for manual oper...:
Can you mount a 4011 as a parallel arm like the 4111?
Resolution:
The 4011 can only mount on the Pull Side of the door and the 4111 can only mount on the Push Side of the door. Differences - The 4011 and the 4111 cylinders are different and the pinion shafts are...:
What is a 62A shoe used for?
Resolution:
The 62A shoe is used when it is necessary to install the door closer (lower) down on the door so that it will operate under accessories such as overhead stops, coordinators, etc.:
In what direction should the hold open nut be pointing for a 4041 H closer, up or down?
Resolution:
Make sure that the hold open nut is not on upside down. The orientation of the hold open nut depends on the mounting. On a Top Jamb "Push Side" mount, the hold open nut would poi...:
What causes a Senior Swing door to hang open and not close?
Resolution:
First, turn off the power to the Senior Swing. If the door closes, check controller for a constant activation signal from an activation device. If door continues to hang up and will not close...:
What power operator is recommended/used for occasional activation with mainly manual traffic?
Resolution:
The 4630/4640 Series operator is designed/recommended for a door that will see mostly manual traffic with the occasion automatic/ handicap operation.:
What options are available on the CE-Series doors?
Resolution:
CE Series door in a variety of embossed panel designs and gages. The CE series embossed panel doors also offer a wide range of specifiable options including sizes, and hardware prepar...: