Allegion
Terms of Use
Privacy Policy
Frequently Asked Questions
Ask your question
Entering your question as a complete sentence will provide more accurate results than keywords or phrases.
User questions
FAQs
Category List
“
current draw falcon
”
RELATED FAQS
Question
Answer
Are there autoCAD drawings available for Allegion products?
Resolution:
AutoCAD drawings are proprietary and are not available for distribution. :
What are the power requirements for the 8310-865 (433 MHz) receiver?
Resolution:
The input voltage for the 8310-865 (433 MHz) receiver is 12-24 VAC/VDC +/-10%, the current draw is 250mA (0.25A).:
Can a Von Duprin delay egress controller DE5101 run a pair of doors?
Resolution:
One Delayed Egress Controller (DE5101) can run two mag locks on a pair of doors, provided the doors are not controlled independently:
What current should an AD-Series or CO-Series lockset draw while in its low power "Sleep" mode?
Resolution:
Use a multi-meter in series with the batteries to measure battery current. Be sure your multi-meter can accurately measure very low current, in the micro-amp range. See the attached Technical Not...:
What is the draw amperage for the E996L?
Resolution:
PS902 is a 2 amp power supply and each E996L electric trim draws 0.25 amps at 24VDC. You can have up to eight E996L electric trim per PS902 power supply.:
What are the MA lock electrical requirements?
Resolution:
For additional details and a wiring diagram see the MA service manual page on electrical requirements here.:
What is the power draw of a Senior Swing series operator?
Resolution:
The Senior Swing (2800/9500) Series operator has a 120VAC @ 2.5 Amp current draw for a single door (2811/9531/9542) or simultaneous pair(2853/9553). The independent pair units (2863/...:
What is the amp draw of the LCN ME and SE closers?
Resolution:
24 volt version draws 90 mAmps (0.090A). 120 volt version draws 30 mAmps (0.030A). See here for the LCN catalog sheets that contain this information (page 2 of 48). :
What is the current draw of a Von Duprin exit alarm kit ALK?
Resolution:
The current draw of a Von Duprin exit alarm ALK is .25 amp when alarm is activated.:
What is the input / output of the 8200 series operator?
Resolution:
The Falcon 8200 series operator requires a input of 120 VAC @ 1 Amp.: