conduit in metal door

RELATED FAQS

Question
Answer
As of February 2016, ND locks began shipping with a new latchbolt. The new latchbolt offers substantially improved performance in adverse door conditions (ex, with heavy door loading) andis more ro...
Prior to February 2016, using ND-Series locks on hollow metal doors required the use of latch spacers which prevent the latch from "fishtailing" (back end of latch moving from side to side). Latch ...
CAD drawings are available for doors and frames in 3 drawing formats: Autocad (.dwg) - Release 12 Encapsulated PostScript (.eps) Data Exchange (.dxf) Drawings are available on the...
The 8847-F is for hollow metal doors only and can not be used on Wood doors.
The Von Duprin 9947 metal door device can be converted to the 9947WDC wood door device by purchasing conversion kit number 050134-XX. This conversion kit is only for the panic version only. Fire ...
1 3/4" is the standard door thickness. Steelcraft only makes a nominal 1 3/4" thick door. A 1 3/8" was made for light duty commercial applications but that product was discontinued in 1999.
Yes, for Panic devices only by ordering the top rod kit part #050574, bottom rod kit part #050575, and screw pack #090061. Fire Rated devices can NOT be converted and would require a compl...
A designer series metal cover is an option with the 1460 series closer, the part number is, 1460-72DS1.
Please contact Technical Product Support at 877-671-7011 option 2 for assistance.
Steelcraft frames and doors are furnished with a high grade, low gloss, baked-on prime paint that provides the best possible protection against corrosion, abrasion and weather, and is an excellent ...
DISCONTINUED: The Falcon T lock had a reinforcement kit for a 1 3/4" thick hollow metal door that prevents lateral movement of the latch. It is a piece of hard foam shaped like a doughnut...
Raceway availability: Optional factory installed raceways are available in doors but are not available in frames. Preparation Info: Steelcraft installs a flexible 1/2" ID steel conduit through the...
Electrical hinges or a power transfer units are the most commonly used practices to run electric power to locks and/or strikes. Electric Hinges: Most electric hinges will fit into a standard 4 ...
A raceway in a door provides a clear wiring access through the door core from hinge to lock edge. In a steel (hollow metal) door, the raceway is typically a length of conduit installed during d...