Does the old style 4030 have the same templating as the new style 4031?
Resolution:
The old 4030 series was: Handed Mounted regular arm hinge side. Had sized springs, were not adjustable. The 4033 is an obsolete closer. If required, handing can be verified by looking at ...:
Why won't the 5100 24v strike work on both a RH & LH door?
Resolution:
The 5100 strike details are listed below: Only operates with 12VDC or 24VDC power supply. Will not operate with AC transformer. 12 or 24VAC can be converted to 12/24VDC using Von Duprin SO12 o...:
How do I determine the hand of a door?
Resolution:
Go to the push side of the door opening. See above illustration. If door swings out to the left, it needs a left hand door closer. If door swings out to the right, i...:
What types of steel are used in commercial steel doors?
Resolution:
The three most common steel types are cold rolled steel, galvannealed steel, and galvanized steel. Cold Rolled Steel (CRS) is suitable for most interior applications, is uncoated steel a...:
How do I change the hand of a hotel cylinder?
Resolution:
HANDINGA stop ring is installed on the right side for right hand operation and on the left side for left hand operation. Right hand shown below.: