closer for pull side double egress

RELATED FAQS

Question
Answer
An LCN 4040T with a reveal deeper than 1/8" on the pull side of the opening requires a Double Egress (DE)arm. ST3073 Standard 4040T DE Arm will accommodate reveals up to 2-11/16"....
ST-1630 is required when mounting a 4041 or 4040XP door closer regular (pull/hinge) side with a concealed GJ100 or GJ410 series over head stop.
EDA ARM - The EDA arm is a heavy duty parallel arm mount.  The degree of door opening is determined by the template used for mounting. EDA arm closers can only be mounted as a Push Side parallel ar...
Optional closer reinforcements are located at 3" from hinge jamb to the beginning of the reinforcement plate. This applies to Regular Arm, Parallel Arm, Top Jamb. Regular Arm (RA) closer reinfor...
A 1460 Pull Side can be mounted standard template for 180°, frame and trim permitting.
A 4030 Pull Side can be mounted standard template for 180°, frame and trim permitting. 
A 1260 Pull Side can be mounted standard template for 180°, frame and trim permitting.
The 4040SE uses the regular arm for any Push Side mounting (minimum 28" door width). ST-2788 (a special arm and track) can be used to mount a 4040SE on the Push Side of a smaller (narrow) door. Sm...
No, LCN does not have an electronic hold open closer (SE/ME Series) that will provide a solid 180° hold open position. The 3130SE has an adjustable hold open position from 85° to 110° maximum. ...
Fire Rated three (3) frames are available in the following maximum door opening sizes: F and FN-Series frame: 4' 0" X 10' 0" single door opening 8' 0" X 10' 0” double door opening MU-Ser...
Hold Open Closers & Magnets (Fire/Life safety products) provide a wide range of solutions.  Single or multi-point hold open closers Utilize an electromechanical closer. Hold the door o...