closer arm functions

RELATED FAQS

Question
Answer
Cam Lift hinges can only be used with LCN door closers that have a "Regular" style arm.     Manual Closers: Maximum lift dimension is 3/4". Can not be use EDA, CUSH, or Track Arm door closers...
The Falcon SC60, SC70, and SC80 series closers all use the same arm options. The SC91 series uses a different arm from the rest.
EDA ARM - The EDA arm is a heavy duty parallel arm mount.  The degree of door opening is determined by the template used for mounting. EDA arm closers can only be mounted as a Push Side parallel ar...
The (SF) "Swing Free" arm allows the door to be put into hold open position, but then repositioned (swing free) to any other degree of opening without taking the closer out of the hold open mode. ...
Yes, as long as you stay with the like style arm.  Example: replace an RW/PA with HW/PA, replace an EDA with HEDA, or replace a CUSH with HCUSH.
2030 and 5030 are both overhead concealed closers. The 2030 uses a concealed, in the door, track, and a concealed one piece arm. The 5030 uses a exposed double lever arm (like the arm for a 401...
The 1260, 1460, and 4030 regular arm closers on the pullside will allow 180° door opening and can be held open at 180°, frame and trim permitting.
 The correct method (process) for setting the hold open is: The 4010 hold open arms are handed, verify correct hand arm. (R or L stamped on main arm) Loosen the hold open nut. Opened the door ...
This can only be done with universal, non-handed closers:  1250, 1260, 1450, 1460, 4030, 4040XP, and 4050.You would need an xxxx-62PA shoe to adapt from regular arm to parallel arm mount&...
The 4011 can only mount on the Pull Side of the door and the 4111 can only mount on the Push Side of the door. Differences - The 4011 and the 4111 cylinders are different and the pinion shafts are...
The 1260 regular (REG) arm is the same as the obsolete 1070 regular (REG) arm.
The 1460 Regular Arm part numbers are: Regular Arm -- 1460-3077 or 1460-3077L for long arm (must specify finish). Regular Arm with PA -- 1460-3077PA (must specify finish). Regular Hold Open Ar...
It would be unnecessary to use the CNS/Cush arm and the Glynn Johnson overhead devices in the same application, both mechanisms stop the door.
ST-1630 is required when mounting a 4041 or 4040XP door closer regular (pull/hinge) side with a concealed GJ100 or GJ410 series over head stop.
Clear Opening Width for swinging doors is measured (with the door open 90 degree) from the face of door to stop soffit on strike jamb.          &nbs...
The 2010 and 2030 closer are not the same. The 2010 Series closer uses the (larger) 4010 cylinder which requires a 4" minimum frame tube to mount in. The 2030 uses the (narrow) "Pacer" cylinder...
The 1260 closer body has the same footprint (9-1/16" x 3/4") and it mounts in the same location as the 1070 body, but the arm will have to be moved slightly to match the 1260 templating.
 The P1070 was replaced with the 1261 Rw/PA.
If the closer arm is touching the door, it is because the arm or the closer body is not templated correctly. Confirm dimensions are taken from the proper location and make corrections if needed. 
Try the steps below to improve the hold open adjustment. Remove hold open nut  Apply a couple drops of blue loctite to the threads. Re-assemble, and reset hold open. Let loctite set up overn...
When placing an order for a 4041/4040XP Rw/PA with hold open, it would be ordered as a 4041 /4040XP Hw/PA. For an existing Rw/PA requiring the addition of a hold open function, a hold open arm woul...