closed back strike

RELATED FAQS

Question
Answer
Von Duprin 6223 electric strike is the most common closed back strike or the 6221 for open back strike on inactive leaf that can be used with Schlage L9000 or Von Duprin 7500 mortise lock.
The Request to Exit (RTX) switch input can be used as a remote door release.
A single-pole, single-throw switch (e.g., pushbutton switch) must be connected across the RTX input pins.
When the switch changes state (e.g., from open to closed), the CT5000 will change the state of the Strike relay.
Head, Jamb, Hinge Jamb, Strike Jamb, Blank Jamb, Mullion, Open sSection, Closed Section; frame componets
The Benchmark III control has a 24VDC, 2.5 amp power supply, and built in relay for controlling electric strikes or other accessories less than 2.5 amps current load. For a fail secure strike, r...
With a mullion: Use the standard strike 267 With no mullion and inactive leaf being held closed with flush or surface bolts: Use the 2609 double door strike
- AD Series and CO series products require that the Night Latch (NL) screw is installed in the exit device.  Be sure this screw is installed- Exit hardware and strike must be properly mounted ...
OBS, 576A, 576B
You can replace the 6210 spring and lip, part number 050940-00.
***The 6210 electric strike was designed to replace mechanical strikes in existing openings when access control is desired.*** Note: The Best 40H series lock is not listed on the 6210 electric s...
All 6000 series electric strike would require the solenoid be replaced to convert from one voltage to the other.
The center line of the L9000 mortise lock is 7/8" above the center line of the 6211 electric strike. This is the "C" dimension given on the second page of the 6211 template.
The centerline of 6223 is the same as the centerline of the mortise latch bolt.  So the centerline of the mortise latch bolt or center line of the 6223 is 15/32" above the centerline of the device.
The Falcon 25R rim device can be used with 6111 electric strike on single or double doors. Additional Information: The Von Duprin 4854/9854 mullion is required when using 25R with 6111 electric...
 For the backset see the Falcon template above, the "B" dimension would be 3-1/4".
The DS is Dual Monitor Switch for Von Duprin 6000 series electric strikes. DS option cannot be added to a Von Duprin 6000 series electric strikes in the field. It is only available factory inst...
The 6111 electric strike can be used only on non rated openings less bottom rod with pullman top latch (use ES prefix when ordering device). Device back set will change to match the centerline of t...
Not for use in fire rated openings.
The 6216 electric strike was designed only for use with only the Folger Adams 310-3-1 mortise lock with deadbolt. The dead bolt must be retracted manually for the the strike to operate.
The strike will always be DC.  By using a SO24 or SO12(rectifiers) you will be able to convert the AC waveform from a transformer to a DC waveform that will be acceptable by the 6000 series strikes.
Von Duprin doesn't offer any electric strike to fit into 1 1/2" aluminum/metal faced frame.  Minimum requirement to install 6211/6211AL is 1 15/32" mortise depth.
To convert the Von Duprin 6000 series electric strikes from FS to FSE  or from FSE to FS follow these steps: Remove the electric strike face plate. Remove the strike box cover pl...
Part numbers: FS slider, part # 970387 (6211WF/6212WF/6221/6223 only) FS slider, part # 970388 (Except 6211WF/6212WF/6221/6223) FSE slider, part # 970388 (6211WF/6212WF/6221/6223 only) FSE sl...
For all models of 6000 series electric strike, except the 6300 & 6400, the color of the solenoid wires determine the voltage.  Black wires are used on 24VDC solenoids and yellow wir...
This is not a recommended application as the electric strike does not have the same holding force as the XP98/99 rim exit device. The electric strike has 1500 pounds of holding force whereas the XP...
Von Duprin does not recommend using XP98/99 devices with any electric strike.   Von Duprin recommends using the standard 98/99 rim device.  The XP device has 2000 pound holding forc...
The operating temperature for 6000 series electric strike is -20 to 120 degrees Fahrenheit.
The Locknetics 9100 series electric strikes are replaced with Von Duprin 6211 and 6210 electric strikes.   6211 is used for new and 6210 is for existing application. For existing applic...
The 6000 series electric strikes are commonly used on exterior doors but they are not waterproof and are NOT recommended for outside such as on a gate with no protection from the elements.
If the solenoid of the 6000 series electric strike is powered continuously with proper voltage at room temperature, the solenoid can reach 200-220 degree Fahrenheit.
The 893P is not a strike, it is the UL label on a 6000 series strike.  This label will not describe the strike you have.