Can flat plate astragal be installed on inactive door

RELATED FAQS

Question
Answer
Types of astragal offered from Steelcraft are as follows: "Z" Astragal - For information on "Z" astragal types and attachment refer to the TD Manual page 3.3.17. Most commonly used on double ...
Astragal must be applied to pull side of active leaf, since placing the stragal on the inside of the inactive leaf will interfere with the active door closing.
Astragals are required on: 3 hour fire rated pairs: Double doors - swinging in the same direction Double Egress - swinging in opposite directions Fire rated Dutch Doors Fire rated 1 3/4" t...
To determine Actual Door Size, the following values are subtracted from nominal door size (frame opening/order size) Actual Door Size: The largest measured width by height of the door leaf as m...
The standard gap between a pair of doors will be 3/16" when used with a Steelcraft  "Z" astragal. If a wide inactive leaf is requested (no astragal) the gap between the doors will be...
Yes, an automatic operator can be installed on a Dutch door. The operator must be installed on the top leaf of the Dutch door. Only the top half will open unless the top and bottom leaves (se...
Use the 575-2 strike with 9975 device on a pair of 1 3/4" thick doors with overlapping astragal mounting on the exterior of the active door. The strike lip has been cut off to eliminate any interfe...
When factory installed on GrainTech® doors: Finish Stain - YES, top caps, bottom caps and astragals are stained (prior to attachment) to match the GrainTech® door finish. GrainTech® Steel - NO, t...
Z-Astragal, Flat Plate Astragal, Two Piece Astragal, 2 Piece Astragal, Overlapping Astragal, Split Astragal, Integral Astragal, Mortised Astragal