can electric strikes be used with vertical rod devices

RELATED FAQS

Question
Answer
Devices built After 2/28/2011: Use a 1 1/8" - 1 1/4" mortise cylinder with straight narrow cam. (Cam profile same as the Schlage B520-731, see table below for part numbers) Devices built Befo...
 Modular 1-1/8"  Modular 1-1/4"  SFIC and FSIC  Non-Modular Non-IC Conventional  Non-Modular Non-IC Everest Primus  B520-730  B520-731  B520-2...
Yes, the current conversion kits will fit the old style/obsoleted 35 or 35 series vertical rod exit devices. 
You should use the LX switch with the Von Duprin surface vertical rod exit device because the rods are exposed and are vulnerable to attack. IE, the top rod can be grasped and forced down to retrac...
To use the 5547 with an electric strike you would need the ES top rod & latch part number 050656-00 and remove the bottom rod and latch. The 6213 electric strike is recommended with 5547LBR, non fi...
An Astragal is an applied molding attached most commonly to the meeting edge of doors to: Protection against weather conditions Minimize the passage of light between the doors Retard the passa...
The NL key override will not open the door while Chexit rim or vertical rod device is in the arm mode.
The 6111 electric strike can be used only on non rated openings less bottom rod with pullman top latch (use ES prefix when ordering device). Device back set will change to match the centerline of t...
Not for use in fire rated openings.
For non fire rated doors only the 1609 strike would be used on the inactive leaf that is flush/surface bolted or with a *surface or concealed vertical rod device on other door leaf.
The Von Duprin 1609 cannot be used on a pair of fire rated doors. We recommend using the Von Duprin fire rated mortise exit device in lieu of the rim device such as the Von Duprin 5575-F,...