cables max height

RELATED FAQS

Question
Answer
Butt hinges can be used on  doors up to 4' wide and 200 pounds.  There is no maximum door height, just need to add a hinge for every 30" or part there of over 7'.
Steelcraft Paladin PW-Series doors and FP-Series frames meet FEMA Tornado Resistant requirements and have been designed and tested to meet the requirements of FEMA 361 guidelines and ANSI ICC500. ...
Monorail cutouts are typically the upper corner of door. Channels are cut to size welded into door held flush to cutout. We do not supply any covers or plates to finish.
The size monorail cutout is 8" wide x 24" high
Monorail cutouts are only available for non fire rated applications.
Maximum nominal (overall) single door sizes are as follows: L-Series (Laminated Door) 20 Gage = 3’ 0” wide X  8’ 0” high 18 Gage = 4’ 0” wide X 10’ 0” high 16 Gage = 4’ 0” wide X 10...
The maximum door width that pivots have been tested is a 4' wide door.  Any door greater than 4' would shorten the life of the pivots. There is no maximum door height, for offset pivots the ru...
For 33/3549A and 98/9949 cable devices shipped from the factory AFTER 7-15-2016:The door opening height must be specified during order entry. The 33/3549A and 98/9949 cable devices are availab...
 
Falcon Standard Bitting Specs - 018 system Falcon Restricted Bitting Specs - 025 system