bottom rod no holding

RELATED FAQS

Question
Answer
Required top and bottom rod adjustment. Top rod possibly is adjusted too short and not lifting the rod far enough to engage the latch retention which would cause bottom rod to drag floor ...
The following items may cause the exit devices top latch from being held in the retracted position. 1. The top or bottom rods are out of adjustment. 2. The top latch hold back...
Following exit devices 2227/F, 33/3527A/F, 33/3547A/48A/F, 98/9927/F and 98/9947/48/F have similar rod adjustment procedures. All top latches control the bottom latch assemblies. When do...
One of the following items may cause the EL1690 device to retract then release: Incorrect power supply - Verify you have the PS873-2/4TD or PS914-2RS/4RL power supply. Problems with wire gauge...
One of the following items may cause the EL1490 device to retract then release: Incorrect power supply - Verify you have the PS873-2/4TD or PS914-2RS/4RL power supply. Problems with wire gauge...
The 6111 electric strike can be used only on non rated openings less bottom rod with pullman top latch (use ES prefix when ordering device). Device back set will change to match the centerline of t...
Not for use in fire rated openings.
The 8827L-LBR panic only, not fire rated can be ordered LBR.
The 8827 cannot be ordered Less Bottom Rod, but can be installed without the bottom rod.  The device was never tested without the bottom rod, that is why it cannot be ordered LBR.
This is available. If this is a fire rated opening you must use the Auxiliary Fire Latch Kit to maintain your Fire Rating.  If not fire rated simply omit the bottom rod but be aware that your...
Installation should be 6" from bottom of the door. See attached templates as reference.  T-5494 for HM Doors W-5494 for Wood Doors