Auto operator does not work is activtated when door is locked

RELATED FAQS

Question
Answer
The overhead concealed operators (2850/2860) will not work on a Double Egress frame because the doors are not in the same plane. You will have to use the surface mount (9553 / 9563) on Double Egres...
The 4600 series operator will not be damaged when trying to open against a locked door. The 4600 series operator has an internal current sensing circuit that will shut down the operator when it see...
Chexit devices are NOT electric latch retraction.  In order for Chexit device to operate with an auto operator you will need to add a rim electric strike on a single door or a pair o...
Use the PS902-2RS power supply with LCN auto operator on single door, PS904-2RS power supply on double door and PS904/906-2RS-2RS for 2 pair of QELA is required for basic operation with a...