are there maintenance documents for electric strikes
”
RELATED FAQS
Question
Answer
What electric strike can be used with the 1790?
Resolution:
None of the Von Duprin electric strikes will work in a retrofit application where the normal standard mechanical strike is mounted to the frame because none of them are thin enough to fit in...:
What is the replacement for the Locknetics 9100 series electric strike?
Resolution:
The Locknetics 9100 series electric strikes are replaced with Von Duprin 6211 and 6210 electric strikes. The 6211 is used if the frame is being replaced. The 6210 is for ...:
What is dual switch monitoring or DS?
Resolution:
The DS is Dual Monitor Switch for Von Duprin 6100 and 6200 series electric strikes (not 6300 or 6400)DS option cannot be added to a Von Duprin 6000 series electric strikes in the field. It is only ...:
What is the part number for the 6210 spring and lip replacement package?
Resolution:
You can replace the 6210 spring and lip, part number 050940-00.:
How do you wire an electric strike to a 4600 Series operator?
Resolution:
The 4630/4630 operator has a 12 VDC and 24 VDC output that can power an electric strike or maglock. The wiring diagrams are shown on page 14 of the installation instructions (attached). 4600 Insta...:
How to convert the Von Duprin 6000 series electrical strike from Fail Secure to Fail Safe or Fail Safe to Fail Secure?
Resolution:
Part numbers: FS slider, part # 090591 (Use for all EXCEPT 6211WF/6212WF/6221/6223. See 090798 below) FS slider, part #090798 (Use this slider for FS models 6211W...:
What is the power output of a 4600 operator?
Resolution:
The 4600 Series operator has both a 12VDC and 24VDC output rated at 1A (combined load) to power strikes, maglocks, and other devices, but an EL device "always" has to have a separate PS914-2RS Seri...:
Will the 9100 series Benchmark III power an electric strike?
Resolution:
The Benchmark III control has a 24VDC, 2.5 amp power supply, and built in relay for controlling electric strikes or other accessories less than 2.5 amps current load. For a fail secure strike, r...:
What is the device backset when using a 1790 with a 6111 strike?
Resolution:
The Von Duprin 6111 electric strike would work with DOM 1790 device on medium style doors Centerline of the 1790 device mounting screws are located 1 11/16" from face of stop. See d...:
What is the difference between LR and PL latches on Von Duprin 8827 exit devices?
Resolution:
ES (electric strike) latch is only used with the 8827 less bottom rod on a non fire rated exit device with a 6111 electric strike.:
Can the Von Duprin 5100 electric strike be used on a pair of doors?
Resolution:
The following application information apply to the 5100 electric strike: Can only be used on a single door with a cylindrical lock Can not be used on a pair of doors Can not be used on a mullion:
Why won't the 5100 24v strike work on both a RH & LH door?
Resolution:
The 5100 strike details are listed below: Only operates with 12VDC or 24VDC power supply. Will not operate with AC transformer. 12 or 24VAC can be converted to 12/24VDC using Von Duprin SO12 o...:
Will the 6210 work with the Best 45H? If not is there another electric strike that is compatible.
Resolution:
***The 6210 electric strike was designed to replace mechanical strikes in existing openings when access control is desired.*** Note: The Best 40H series lock is not listed on the 6210 electric s...:
Can the 6300 electric strike be Fail Safe?
Resolution:
The Von Duprin 6300 surface mounted electric strike is only available as Fail-Secure.:
Is a rectifier needed to change AC to DC on Von Duprin 6000 series electric strikes?
Resolution:
The strike will always be DC. By using a SO24 or SO12(rectifiers) you will be able to convert the AC waveform from a transformer to a DC waveform that will be acceptable by the 6000 series strikes.:
Is there an electric strike that will work with the 2670 Guard X?
Resolution:
The Von Duprin 2670 Guard X does not have a spring loaded latch bolt, it is a dead bolt and will not operate with any electric strikes.:
Will the 6300 electric strike work with the 22 series rim device?
Resolution:
The 6300 surface mounted electric strike can be used with a 22 rim device.:
Is there a monitor switch for the 6300 electric strike?
Resolution:
There are no optional monitor switches available for the 6300 electric strike.:
What is the most common practice for running electric power from a frame to the door and hardware?
Resolution:
Electrical hinges or a power transfer units are the most commonly used practices to run electric power to locks and/or strikes. Electric Hinges: Most electric hinges will fit into...:
How to determine the voltage used by a 6000 series electric strike?
Resolution:
For all models of 6000 series electric strike, except the 6300 & 6400, the color of the solenoid wires determine the voltage. Black wires are used on 24VDC solenoids and yellow wir...:
Can 5100 electric strikebe used on fire rated door?
Resolution:
The Von Duprin 5100 electric strike is not for fire rated applications.:
What is the part number for a blade stop shim for a 6111 or 6113 electric strike?
Resolution:
010055-xx is the part number for Blade Stop Shim kit for 6111 or 6113 electric strike and it must be ordered separately. xx is for the finish callout.:
Can you power a electric strike from the 7900 control boxes?
Resolution:
The power supply output in the 7900 series control box is a 12VDC output, rated at (1/4A) 0.250A. It cannot be used to power a strike or maglock. You need to have a separate power supply for the st...:
What is the amount of pre-load force allowed for the 6300 electric strike before the strike will no longer release and operate properly.
Resolution:
The 6000 series electric strikes 6100, 6200, 6300 models, require that there be no preload at all on the strike lip to function properly.:
Can the 6111 electric strike be used with Falcon 25R?
Resolution:
For the backset see the Falcon (F)25-R template; T-1201 for Metal Door, W-1201 for Wood Door. For Single Doors, the distance from the surface of the raised stop to the Centerline of the device is...:
Will the 6300 work with the 55 rim?
Resolution:
The Von Duprin 6300 surface mounted electric strike is compatible with 55 rim device.:
Will the 6300 electric strike work with 88-F or the 88 rim panic?
Resolution:
Von Duprin 6300 electric strike will operate with 88 rim but not 88F fire rated exit devices.: