are LCN door closers fire rated

RELATED FAQS

Question
Answer
All LCN closers have UL listings, and are Fire Rated for up to 3 hours.
The 3130 Series closer is UL listed- Fire Rated (UL-10C) for up to 3 Hr.The Door and Frame Manufacturer needs to be contacted to verify their Door/Frame rating would not be compromised wh...
615R is not a door closer model number. It is a UL number for the Falcon SC Series closers.
Yes, the Falcon SC Series closers have a UL listing.
Any LCN Closer that ends in the number 1, will meet ADA 5 lbs opening forces.
The old 4030/4130 closers and arms are obsolete, there is nothing to replace them. No arm from other closers will fit  There is no closer that can replace the old 4030 series closer with the exa...
STANDARD ROD AND SHOE: 4020, 4031, 1460, 1520, 1370, 1070, 1260, 4640, 4820 is: 8 3/8” LONG ROD AND SHOE: 4020: 4031, 1460, 1520, 1370, 1070, 1260, 4640, 4820 is: 12 3/8” STANDARD ROD AND SHOE: ...
How to:  What are the steps to adjust a door closer?Facts: All LCN and FALCON door closers will have 3 regulating valves and a spring adjustment.  All closers with a "Delay" feature ...
Special Rust Inhibitor (SRI) - is a pretreatment that is applied to the metal components prior to the addition of the LCN powder coat finish, standard or custom. ...
There are a few things that can cause a closer to slam. The closer could be adjusted incorrectly. Turn all regulating screws clockwise until they stop. Then open each valve 1 and 1/2 turns. If t...