Allegion
Terms of Use
Privacy Policy
Frequently Asked Questions
Ask your question
Entering your question as a complete sentence will provide more accurate results than keywords or phrases.
User questions
FAQs
Category List
“
are continuous hinges available lead lined
”
RELATED FAQS
Question
Answer
Does Ives offer a continuous hinge or pivot for lead lined doors?
Resolution:
Ives does not offer a continuous hinge designed specifically for lead lined doors. Standard hinges may work if the hinge and mounting hardware do not penetrate the lead lining in the door.&nb...:
Where is common cutout for Von Duprin EPT prep in Ives 224 Continuous Hinge?
Resolution:
Cutout depends on the size of 224 hinge. See 112HD/224HD-EPT template. 112HD/224HD continuous hinge Center line of EPT to top of the door 83 inches 30 inches 85 inches 32 inc...:
Do you sell lead lined pivots?
Resolution:
Ives does not offer any lead lined pivots. An appropriate model of pivot would be determined by the weight of the door and where the lead lining is in the door. Because ...:
What is the template for the 224HD TW8 continuous hinge?
Resolution:
Templates for 224HD TW8 continuous hinges are 829431-00 for 83" & 85", 829433-00 for 95" & 829435-00 for 120" tall doors. Templates for 112HD TW8 continuous hinges are 829430-00 for 83" & 85", 82...:
Does the door prep need to be altered when ordering the L9000 locks lead lined?
Resolution:
The door template L1 states: "Lead Lining: When L9000-Series or L400-Series locks are ordered with lead lining, add 1/8" to the width of the mortise cut-out on the lock case cover side of installa...:
What is the standard downsizing for a door leaf when using continuous hinges?
Resolution:
Doors require special downsizing for continuous hinges. The amount of downsizing depends on the hinge specified (manufacturer and type) and the hinge application (Full Mortise versus Full Surface v...:
Is lead lining a GJ overhead an option or even needed when used in an X-ray room?
Resolution:
Lead lining is not needed, since the channel or through bolt is solid and the x-rays will not penetrate the solid metal.:
Are Lead Lined covers needed for LCN Closers?
Resolution:
The determination was made that Lead Lined covers are no longer needed for the LCN product line, see below Marketing/EHS document. Lead Lined cover discontinuation letter :
Where is the EPT location of a Pin-and-Barrel Continuous HInge?
Resolution:
The 600/700 Series EPT Template shows recommended locations based on the standard sizes, The customer can provide a different dimension measured from the top of the hinge to the Cen...:
Why are lead lined frames used?
Resolution:
Lead lined frames are intended for use in the X-ray Room locations in Health Care facilities. Frames are provided by Steelcraft prepped as follows: Frames are supplied knock-down (KD). Fram...:
What is the standard gap between a pair of doors hung with continuous hinges?
Resolution:
The standard gap between a pair of doors will be 3/16" when used with a Steelcraft "Z" astragal. If a wide inactive leaf is requested (no astragal) the gap between the doors will be...:
What hinges can be used on tornado doors?
Resolution:
The following hinges are available on Paladin series doors and frames: Butt hinges - 4 1/2" or 5" ball bearing type either standard or heavy duty Continuous hinges - full ...:
Where is the Fire Label located on a door and a frame?
Resolution:
Fire labels (UL, ITS/WHI or FM) are located as follows: Butt Hinges and Pivots: On the doors the fire label is located on the hinge edge between the top and 2nd hinge preparation. On the fram...: