ALK not working

RELATED FAQS

Question
Answer
Followings are the reason for 98/99 exit alarm ALK not sound when push bar is activated. Make sure key switch on exit alarm ALK is turned on, wait for 20 seconds before you activating the pushba...
The PS9 power supply was discontinued.  The new exit alarm ALK can either use a 9VDC battery or 24VDC regulated power supply. There is no direct replacement for Von Duprin PS9 power supply. Cur...
If the spring on the Von Duprin exit alarm ALK board is not located correctly as shown on the instructions, then the vibration from the horn allows the cylinder to turn and shut the exit alarm ALK ...
Depends on what is being ordered; SS can stand for either the "Signal Switch" or the "Silk Screen" push bar. The SS (Signal Switch) and ALK (Exit Alarm) sit in the same location in the exit devi...
PCB only for the Alarm Kits prior to June 11th, 2012 is part #650335 and was used in the older 17 & 18 devices, 19, & pre June 2012 24/25's.
This circuit board will NOT work on the updated 24/25 Alarm Kits that released June 11th, 2012.
The Von Duprin exit alarm ALK shipped after November 2010 are new style boards and can be identified by the 3 terminal blocks and LED.  Only these ALK will work with 24vdc power supply.
The new exit alarm ALK uses the 24VDC regulated PS902 power supply.
There are three main failures with an ALK.  Problems are usually caused by a bad power source(battery), bad RX/LX Switch or a bad circuit board.  Try installing a new battery and wai...