Alk alarm sounds whened arm
”
RELATED FAQS
Question
Answer
The Von Duprin 98 or 99 ALK kit will not sound the horn
Resolution:
Followings are the reason for 98/99 exit alarm ALK not sound when push bar is activated. Make sure key switch on exit alarm ALK is turned on, wait for 20 seconds before you activating the pushba...:
Why is the Von Duprin exit alarm ALK going into alarm on it's own?
Resolution:
The following may cause the ALK to go into alarm: Make sure red and blue wires on the RX switch are connected to the exit alarm ALK terminal block and yellow wire is taped off. Check the red an...:
Why would the ALK chirp?
Resolution:
A low battery could cause the exit alarm ALK to chirp. Replace the battery and if it is still chirping, then replace the circuit board part number 101030-00.:
Will an ALK sound when the exterior trim is used to enter from the pull side?
Resolution:
The ALK exit alarm will sound when the exterior trim is used to enter from pull side without using access control when an LX latch bolt monitor switch is used instead of RX push bar monitor switch.:
Can the Von Duprin ALK exit alarm be ordered with hex dogging option on?
Resolution:
The standard exit alarm ALK devices are not available with dogging option. The device can be ordered through Engineering Special with dogging option on non fire exit devices. This special is o...:
Can I use CD and ALK on a 98/99 series Von Duprin?
Resolution:
Standard 98/99 exit alarm ALK devices are available with cylinder dogging option as of October, 2011. The device can be ordered standard with cylinder dogging and exit alarm ALK opti...:
What is the current draw of a Von Duprin exit alarm kit ALK?
Resolution:
The current draw of a Von Duprin exit alarm ALK is .25 amp when alarm is activated.:
If using the alarm kit-ALK with the 99 device what power supply is needed?
Resolution:
Exit alarm ALK operates with 9VDC battery and doesn't required a power supply.If you choose to hard wire the exit alarm ALK use the PS902 power supply.Exit alarm ALK requires 24VDC regulated power ...:
Can the Von Duprin Chexit device be changed to ALK exit alarm?
Resolution:
The Chexit device has a different base plate and center case than the ALK. The Chexit device would need to be replaced with an ALK device.:
What would cause the Von Duprin delay egress Chexit device not to provide delay egress?
Resolution:
For Solenoid driven Chexit devices shipped from the factory prior to 8-24-2015, the following could cause the device not to provide delay egress:Measure the voltage between green and orange wires o...:
What would cause my Chexit to go into a weak alarm 10 seconds after arming it?
Resolution:
The following could cause the Chexit device shipped prior to 8-24-2015 with solenoid driven to go into weak alarm with solid LED light: Wrong power supply- Chexit device requires a...:
What could cause the Von Duprin exit alarm ALK to turn off after one or two minutes?
Resolution:
If the spring on the Von Duprin exit alarm ALK board is not located correctly as shown on the instructions, then the vibration from the horn allows the cylinder to turn and shut the exit alarm ALK ...:
What is the part number for the ALK sign?
Resolution:
The sign for exit alarm, ALK, is SIGN-1.: