al lock series conversions

RELATED FAQS

Question
Answer
The new AL FSIC driver part number is A700-052.  This driver snaps onto the back of the core similar to the ND, as opposed to it being assembled into the lock chassis with a retaining ring.  Th...
Changing the plunger assembly on the AL-Series requires disassembling the chassis.  Refer to Plunger Assembly Instructions for guidance.
The easiest method to obtain an AL lock for a 2" door is to specify a 2" thick door when ordering.  
Part required by function:2 each A700-043 driver & A700-034** lever insert in addition to the chassis parts below:AL10S – 2 hubs A700-028AL25D – 2 hubs 1 A700-028 (inside), 1 A700-030 (outside)...
Schlage offers the AL170 single dummy trim, but for applications where a double dummy is needed you can install two AL170 dummy trims back-to-back.  Each AL170 is shipped with a threaded rod (part ...
SCHLAGE locks are available with the following backsets: Lock Series Lock Type                 ...
The AL lock is a Grade 2 lock ANSI/BHMA Certified A156.2-2003, Series 4000, Grade 2, UL Listed for 3-hour fire door.
The process to change the Credential Reader on an AD-Series lock is as follows: Note: To ensure firmware compatibility of the lock and reader, it is important that the firmware in the LOCK and the...
There was a design change in 2001 for the driver and lever insert on the AL for SFIC products.  Changing the driver and/or lever insert on locks manufactured prior to 2001 will requi...
 The SFIC lever insert part number prior to 2001 was the A700-022.
 Falcon T Lock Latch Conversion Table       Effective mid-June 2013  Old Part Number   New Part Number       ...
   Falcon T Lock Latches No Longer Offered With The T Lock     Effective mid June 2013  Old Part Number  New Part Number   &nb...
In 2002 the Schlage AL-Series underwent a design change that affected the spring cage, driver, and plastic insert.  Spring cage and driver replacements for AL locks manufactured before this design ...
The standard door range for an AL lock is 1 3/8" to 1 7/8".  Using the supplied instruction sheet, align the springcage post to desired door thickness by adjusting the outside castle nut. See inst...
Warranty Statement3 Year Limited Mechanical Warranty and 1-Year Limited Electromechanical Warranty - Additional warranties listed below The provisions of these limited warranties do not apply to P...
Reference the L-Series Service Manual to change lock functions or build up a case from parts.
This Step-by-Step guide is specifically designed for the functions listed below, however, it can be referenced with a majority of L series functions since most of the parts are ...
The 98/99 rim and vertical rod exit devices are shipped with NL drive screw to function as a Night Latch. To convert the device to Class Room, remove the NL Drive Screw on 98/99 center case ass...
BAA/ARRA stand for Buy American Act and American Recovery and Reinvestment Act. A brief description of some of the federal requirements can be found in the BAA Catalog on the Allegion...
Country of Origin (COO) information can be found in the Buy American Act (BAA) brochure.
To obtain product certification forms:Download the BAA Catalog on the Allegion website Complete the information requested in the the BAA Catalog with a detailed copy of the prod...
Re-classing is the process by which an AD-Series device is able to change its lock type. The AD-Series has a modular architecture and a major benefit of this type of architecture is that it allows ...
In mid-May 2013 the Falcon T-Series changed the slide and catch spring used in the chassis to improve overall durability.
On power-up the CO-Series locksets will provide 5 quick RED Schlage Button flashes and 5 quick beeps to indicate that the electronics (credential reader) has been changed.  In order to recover...
When/If the electronics (Credential Reader) changed on a CO-Series lockset, the lock will respond with 3 RED Schlage button flashes and 3 beeps for any key press or credential presentation.&nb...
CO Reader Modules cannot be replaced by Reader Modules with a different credential type; for example, a magnetic swipe credential reader cannot be replaced with a proximity credential rea...
A Credential Reader MAY be replaced with another Credential Reader of the same type; however, a Factory Default Reset must be performed before the lock will function properly.
The RU lock is factory handed for a Left hand or Right hand door.   For reverse handing ( Left hand reverse and Right hand reverse doors) see step 9 of the installation instructions for rehanding d...
As of May 23, 2011 the Schlage H-Series is assembled with the Schlage B500-Series deadbolt and a new linkage. If the deadbolt is being replaced for a lock manufactured prior to May 23rd, 2011...
Grade 2 locks are tested and certified to be in compliance with the following ANSI/BHMA Standards: Cylindrical, Bored and Preassembled Locks & Latches 400,000 Certified Cycles ANSI...
The AL-Series has four distinguishable parts that can help in lock identification.     1.   The AL-Series will have a castle nut holding the chassis on the ...
CO-100 now allows the PIN code length to be changed manually.  Each CO100 has a label that indicates its firmware revision.  Firmware revision 2.5.0 or higher support these...
CO-100 PIN length can range from 3 digits to 6 digits with firmware version 2.5.0 and higher.
Procedure to change PIN length: 1. Press {programming code (default is 97531)} then {*}.2. Press {99} then {*}, to enter Special Function Length Menu.3. Press {4} then {*}, to enter Pin Length M...
CO-100 now has NEW lock status reporting capabilities. Battery status, firmware version, hardware version and PCB serial number. See instructions below for these status menus.
The Von Duprin 7500 mortise lock body ships in the NL mode.  Either the function of 7500 lock body has not been changed to the Classroom function or the NL Drive screw is not all the way down. Step...
  Tips for changing the function: The NL Drive screw will not be visible when lock body is set to Classroom function There is locktite on the screw that makes it seem like its turned down enou...
When you want to periodically disable and block access to a certain room in a building or an entrance door, that’s when you would need to use a Lockout Cylinder. See full document.
Changes to the Falcon W501 latch offering were made on 2/13/2012.   Prior to 2/13/2012: The W501 entry lock was supplied with a restoring latch which causes the button to pop and unlock...
On ND locks manufactured on or after January 30, 2017 only the SFIC lever and SFIC driver are needed to convert the lock from Full Size conventional (PD) or Full Size IC (JD, RD, TD) prep to S...
On ND locks manufactured prior to January 30, 2017, the lever, spring cage and tailpiece needed to be replaced with the SFIC lever, SFIC spring cage and the SFIC driver . N123-056 - Outside sp...
Causes for AA battery drain in AD-Series LOCKS Possible Cause Fix/Corrective Action 1)      One the four (or eight) AA was inserted reversed and the rese...
Causes for AA battery drain in CO-Series LOCKS - Possible Cause Fix/Corrective Actions  One of the four AA batteries was inserted reversed and the reserved battery drains the other batteries. ...
The AL and ND locks are not available in any stainless steel finishes.  The only option is either the 626 satin chrome or 625 bright chrome.
Order the M204-198 thru-bolt jig, see Figure 1. Figure 1: M204-198 thru bolt jig The 40-080 was the old Schlage jig. The 030736-000-70 was the old Falcon jig.  When the jig changed to...
The AL and A trim is not compatible with each other.
The AL series product line does not use any parts that requires prior knowledge of the door handing.  
Refer to table 1 for the list of Schlage AL-Series cylinders.     AL-Series Cylinder Reference Table    Function  Cylinder Mechanism   Complete Cylinder   Non-Hotel Functions  ...
The AL series lock fits up to 1 7/8” door thickness out of box.