ad lock classroom security

RELATED FAQS

Question
Answer
Apartment Corridor Lock function is defined as a lock where the latch bolt operated by lever from either side, except when outside lever is made inoperative by a stop or mechanical means other than...
-On the AD series offline locks only you can change the lock function from Classroom/Storeroom to a Privacy, office or apartment function out in the field. - This is done via the HHD/SUS using...
Von Duprin offers two options:The CDSI/HDSI Dogging Indicator provides an at-a-glance verification of the status of the door from inside of the room. Visible “LOCKED” and “UNLOCKED” indicators show...
Classroom security lock* two-point latch - Latchbolt(s) retracted by lever from either side unless locked by key from either side. When outside is locked, latchbolt(s) retracted by key and lever ou...
Classroom security lock with deadbolt - Latchbolt is retracted by knob/lever from either side. Deadbolt is operated by key from either side. Throwing deadbolt locks outside knob/lever. Turning insi...
Classroom security lock with three-point latch - Latchbolt is retracted by knob/lever from either side unless locked by key from either side. When outside is locked, latchbolt is retracted by key a...
L9071 LV9071 (ANSI F32) Classroom Security Lock  Latchbolt retracted by knob/lever from either side unless outside is locked by key from either side. Auxiliary latch deadlocks latchbolt when door...
Place any new orders per the following table ...
 Mortise Deadbolt Locks  Discontinued  Replace With  CO200MD  70-Classroom/Storeroom  40-Privacy  CO250MD  70-Classroom/Storeroom  40-Privacy  AD200MD  70-Classroom/Storeroo...
* NOTE: the AD300/400 devices simply communicate the change in Deadbolt Position status to the Host software.  The software then decides what action should or should not be taken at the device. 
The Schlage CO-220 is standalone classroom lock down solution with remote fob and visual indicator which allows immediate local lock down by simply pushing the button on the remote fob from anywher...
The minimum door thickness that the AD or CO series lock will mount on is 1 3/8".  Be advised that this will require additional spacers to be ordered separately to allow the lock to mount...
Out of the Box, or after a Factory Default Reset, all AD locks can be used in a "Construction Mode".    At launch ...   The AD-Series locks would accept the first card credentia...
Update your device firmware to the latest version to fix this early design / feature update
ND locks shipping on or after January 30, 2017 will have redesign levers that will not work with the AD cylindrical locks.
Prior to January 30, 2017 the only AD levers that were the same as the ND are on the AD units with the cylindrical chassis style.The AD mortise, mortise deadbolt, or 993 exit trim, the le...
If the error "Device does not support this action - E802" appears when trying to couple the lock, it is generally because the user is not pressing the SW1 tamper button 3 times, but instead pressin...
In order to properly couple, the interior pushbutton must be held down while tapping the SW1 (tamper switch) three times.  This will enable the lock to couple to the HHD.
All Keypad ONLY credentials with firmware versions between 2.9.2 and 2.11.0 should be updated to the latest firmware available at www.schlage,com/support.
A firmware issue with Keypad ONLY credential firmware, versions 2.9.2 through 2.11.0 and manufactured between 9-9-2010 and 1-5-2011 will exhibit poor battery life.
The Keypad ONLY credential Reader (KP) can prevent the reader from entering its low power sleep mode - with firmware versions 2.9.2 through 2.11.0
A Technical Note has been generated to document one method of measuring battery current. See the attachment HERE.
Installers have reported that their AD-CO Series cylindrical or mortise locks will unlock whenever the outside lever is lifted.    This will occur if the outside spindle (square post) is install...
The JD YA6 tailpiece is intentionally designed such that the tailpiece cannot be installed at the same time as the cylinder.  Interchangeable cylinders assume that the lever and taipiece is in...
See the JD Yale Lever installation instruction HERE
If the  AD300  power is not correctly connected it may not communicate or other wise function correctly.The AD-Series locks must be hard wire powered through the comm board. It is not com...
The original 4B battery holder used with the AD and CO Series products is updated to improve performance.  The issues addressed include: -    New ledges are added near eac...
The original 4B battery holder used with the AD and CO Series products is updated to improve performance.  The issues addressed include: -       Improved spring ...
Schlage has conversion kits to convert the classroom L/LV9070 to the classroom security L/LV9071 and the classroom holdback L/LV9076 to the classroom security holdback L/LV9077.  The...
Conversion kits are available to convert many popular functions.Conversion kits manufactured on or after January 30, 2017 will have the new enhanced ND spring cage, lever, plunger and buttonCo...
For all available ND Series Conversion Kit part numbers, click here.
As of August 26, 2013, the ND75/95 in 626 finish comes standard (no additional charge) with indicator rose with black lettering and indicator arrow.For locks that shipped prior to August 26, 2013, ...
 Component  Function  Product  How to Order  Rhodes Indicator Rose  Classroom Security  ND75, ND95  XN12-035 (626 only)  Omega Indicat...
See attached bulletin.  Marketing bulletin with associated Von Duprin indicators listed.
If a blank rose is preferred over an indicator rose, the customer will need to order the lock less inside rose and order the inside rose (03-042) separately. Example: Lock Less each rose: Use ...
The process to change the Credential Reader on an AD-Series lock is as follows: Note: To ensure firmware compatibility of the lock and reader, it is important that the firmware in the LOCK and the...
The AD lock  battery pack type can be changed following this procedure:1. Disconnect the existing battery pack2. Depress and hold the SCHLAGE button for a few seconds to drain off any residual...
Re-classing is the process by which an AD-Series device is able to change its lock type. The AD-Series has a modular architecture and a major benefit of this type of architecture is that it allows ...
The coin cell for the AD and CO family of electronic lock products is a 3vdc lithium. CR2025 is the specified part number.
The AD and CO locks both have a 3 hour fire door rating. Please see URL for more info.  UL Fire Rating List
This information can be found at the following URL's: AD200/AD250/AD300/AD400 Cylindrical http://w3.securitytechnologies.com/irstdocs/installinstructions/102104 P516-092.pdf
AD200/AD250/AD300/AD400 Mortise http://w3.securitytechnologies.com/irstdocs/installinstructions/102106 P516-093.pdf
AD200/AD250/AD300/AD400 Cylindrical Exit http://w3.securitytechnologies.com/irstdocs/installinstructions/102264 P516-094.pdf
AD200/AD250/AD300/AD400 Mortise Exit http://w3.securitytechnologies.com/irstdocs/installinstructions/102263 P516-095.pdf
CO100/CO200/CO250 Cylindrical http://w3.securitytechnologies.com/irstdocs/installinstructions/104214 P516-266.pdf
CO100/CO200/CO250 Mortise http://w3.securitytechnologies.com/irstdocs/installinstructions/104213 P516-267.pdf
CO-Series Cylindrical Exit http://w3.securitytechnologies.com/irstdocs/installinstructions/102297 P516-268.pdf
CO-Series Mortise Exit http://w3.securitytechnologies.com/irstdocs/installinstructions/102296 P516-269.pdf
This information can be found at the following URL's: AD200 http://us.allegion.com/content/dam/allegion-us-2/web-documents-2/UserGuide/Schlage_AD-200_Offline_Lock_User_Guide_-_English_102107.pdf
AD250 http://us.allegion.com/content/dam/allegion-us-2/web-documents-2/UserGuide/Schlage_AD-250_Offline_Lock_User_Guide_-_English_102108.pdf
AD300 http://us.allegion.com/content/dam/allegion-us-2/web-documents-2/UserGuide/Schlage_Utility_Software_User_Guide_6.4.2_104390.pdf
AD400 http://us.allegion.com/content/dam/allegion-us-2/web-documents-2/UserGuide/Schlage_AD-400_and_AD-401_Networked_Wireless_Lock_User_Guide_104387.pdf
CO100 http://us.allegion.com/content/dam/allegion-us-2/web-documents-2/UserGuide/Schlage_CO-100_Offline_Lock_User_Guide_-_English_104210.pdf CO200 http://us.allegion.com/content/dam/allegion-us-...
CO250 http://us.allegion.com/content/dam/allegion-us-2/web-documents-2/UserGuide/Schlage_CO-250_User_Guide_English_104208.pdf
The original Inside Cover (Fig. 6 and Fig. 8) and the new Inside Covers (Fig. 7 and Fig. 9) are all compatible to the original Main PCB but only the new Inside Covers press on the tamper switch in ...
Use a multi-meter in series with the batteries to measure battery current.  Be sure your multi-meter can accurately measure very low current, in the micro-amp range. See the attached Technical Not...
The minimum recommended Stile measurement is 5” to allow proper mounting of the AD and CO series locks.
The original Inside Cover (Fig. 6 and Fig. 8) and the new Inside Covers (Fig. 7 and Fig. 9) are all compatible to the original Main PCB but only the new Inside Covers press on the tamper switch in ...
Dynamic Channel Switching is a feature of the Schlage AD-series wireless access point modules. Dynamic Channel Switching (DCS) increases the robustness of the wireless RF communication in a noisy r...
  Here is a Technical Note on what Dynamic Channel Switching is, what it improves, how to set-up, and frequently asked DCS questions. DCS Tech Note here  
Setting Dynamic Channel Switching   1)     Connect and couple the SUS to the PIM400 you intend to change. See the SUS User Guide for details   2)     Under “PIM Properties” and the “Edit” tab is ...
When new product(s) are added to an existing installed customer site, all devices at that site should be updated to the latest firmware revision that is available.  
 Whenever an AD-Series credential reader is upgraded with new or different credential types or replaced in the field, be sure to update the firmware so that the main and reader have com...
For the most consistence product operation all device firmware revisions should match the new product being installed.  
Ensuring consistent firmware revisions across your facility will guarantee that all of the installed customer products will act and respond the same durng use and programming.  
Products updated with the latest available firmware will also include the latest feature set(s), improvement performance and/or bug fixes  
Go to the Schlage support site to download the latest firmware package  - www.schlage.com/support  
Steps to determine what firmware version your products are currently using AND if a firmware update is suggested: Use the Hand Held Device (HHD) and Schlage Utility Software (SUS) application to...
When new product(s) are added to an existing installed customer site, all devices at that site should be updated to the latest firmware revision that is available.  Whenever an AD-Series&nbs...
 
 
 
Yes, several HHD's can be used with a single lock, as long as the HHD's have the same Coupling Password as the lock.
The HHD coupling password is set during the lock initialization, coupling process.
When the coupling password is changed the value is stored in the HHD and once coupled to a lock, the Coupling Password is also loaded in the lock/device memory.
The Coupling Password is compared whenever an HHD is trying to adjust lock configuration settings or downloading door programming files.
- AD Series and CO series products require that the Night Latch (NL) screw is installed in the exit device.  Be sure this screw is installed- Exit hardware and strike must be properly mounted ...
The AD200, 250, 300, and 400 trims will work with the Von Duprin 98/9975 mortise Exit Devices.
AD300 locksets MUST have hard power to operate.
Connect 12VDC or 24VDC power supply to the AD300 lock before attempting HHD communication.
Update your lockset using ADFwPkg 2.19.0 or higher.  This new firmware update resolves this programming error problem (E701) and the error will no longer be presented.
 See the attached Technical Note for instructions on saving a "Device Template" FROM a device or loading TO a device, Device Template Tech NoteOn the SUS/HHD go to the LOCK Properties tab, and sele...
(2) SCREW, TORX, T-15, #8-32 UNC 2A, UNDERCUT, FLAT HD, MACHINE,  1/4" LENGTH (2) SCREW, TORX, T-20, #12-24 UNC 2A, UNDERCUT, FLAT HD, MACHINE,  1/2" LENGTH (2) SCREW, 8-32 X 3/4 MS PIN TORX (1)...
(4) SCREW, TORX, T-15, #8-32 UNC 2A, UNDERCUT, FLAT HD, MACHINE,  1/2" LENGTH (2) SCREW, TORX, T-20, #12-24 UNC 2A, UNDERCUT, FLAT HD, MACHINE,  1/2" LENGTH (2) SCREW, 8-32 X 3/4 MS PIN TORX (1)...
1.      Remove the inside top cover.  2.      Disconnect the RTX switch from the circuit board.  3.      Set...
ALWAYS put the PIM400 in LINK mode first. On a PIM400-TD2 press the LINK1 Button for door one, and LINK2 button for door 2. With a PIM400-485 you must use the SUS/HHD to select which door to LINK.  
1. To put the AD400 in LINK mode, hold down the RTE (Lever or crash bar see below) and press the # key on the key board, or present a card to the reader.            Why press the # key? Because t...
2. AD400 requires a Request To Exit (RTX) signal to link - see the user guide instructions for the linking process.  For an AD400 to enter link mode, it must see the RTX (Request To Exit) switc...
   3. Check the AA battery level, if the AA batteries are below 4.7 volts the AD400 can fail to LINK.             Install fresh batteries, with a level of 6.0 volts or better.  
4. PIM400/AD400 COM400 plug could be damaged! The small pins in the Main PCB board connection for the RF COMM board can get bent during installation of the RF COM400 board. If the PINs are bent a...
1) Make sure the lock batteries are more than 4.0 volts. The USB connection will not detect or communicate with a voltage lower than 4 volts. Many times a firmware update will draw d...
2) Make sure the SUS/HHD is set to communicate using USB connection mode in SUS.  You should see the familiar USB symbol on the SUS main Screen in the bottom right corner.  If you see a S...
3) When you update with NEW firmware replacing very OLD firmware a S1 RESET is suggested after the update. This initializes all the AD-Series memory locations to the new firmware. S1 is the ...
4) Make sure the HHD-USB cable is securely inserted into the HHD and into the lockset.  
5) Inspect the HHD-USB connector(s), ensure no pins are damaged, recessed or out of alignment. If a damaged cable is found customers should see their dealer for a replacement or they can order a re...
5) If working with a CO lockset, the mechanical key switch needs to be in its "Inactive" or normal position.  Ensure the triangle alignment on the front escutcheon and that...
ALL AD and CO products are warranted for electrical for 1.0 year after installation OR 2.0 years after manufacture. The mfg date is on the lock stickers AND can be viewed electronically with th...
Many problems with AD-series locks can be resolved by performing a Factory Default Reset (FDR).  This process will clear the memory and any stored configurations, re-enabling default...
To perform an FDR on an AD-series lock: 1.     Remove the inside top cover of the lock.  This will expose the main board and activate the tamper switch.   2. &...
Note: An FDR cannot be performed if an HHD is plugged into the lock. 
Customers will need to use the Schlage Utility Software (SUS) on the HHD lock programming device to set the desired magnetic track to be read for access control, if not using default Track 2&n...
The part number for the AD or CO twisted tailpiece kit is: 46929303 Tailpiece Kit - (for Exterior Escutcheon -993 into Exit Device, i.e. Von Duprin 98 or 99) Exit Trim 46929303 Includes the...
ND93PD (ANSI F88) Vestibule LockLatch retracted by key from outside when outside lever is disengaged by key in inside lever. Inside lever is always unlocked.  ND95PD (ANSI F110) Classroom Securit...
Classroom security lock with auxiliary latch - Latchbolt is operated by knob/lever from either side except when outside is locked by key from inside or outside. Deadbolt is retracted by key from i...
Classroom security lock - Latchbolt is retracted by knob/lever from either side unless locked by key from either side. When locked, latchbolt is retracted by key outside or knob/lever inside. Insid...
Classroom Security lock with Vandlgard - Outside lever locked or unlocked by key in either lever. Vandlgard allows outside spindle to disengage from latch when locked. Inside Key locks or unlocks o...
Vestibule/Classroom Security lock - Latch retracted by key from outside when outside knob is locked by key in inside knob. Inside knob is always unlocked.
Classroom Security Lock - Outside lever locked or unlocked by key in either lever. Key locks or unlocks outside lever. Inside lever is always unlocked and is always free for immediate egress
Classroom Security Lock - Outside lever locked or unlocked by key in either lever. - Inside Key locks or unlocks outside lever. Inside lever is always unlocked and is always free for immediate egress
The Von Duprin 7500 mortise lock body ships in the NL mode.  Either the function of 7500 lock body has not been changed to the Classroom function or the NL Drive screw is not all the way down. Step...
  Tips for changing the function: The NL Drive screw will not be visible when lock body is set to Classroom function There is locktite on the screw that makes it seem like its turned down enou...
Information on low battery threshold and nuisance delay is noted below: New firmware now has improved levels. - These are approximate values/levels which change with measurement meters and measure...
AD400/AD200/AD250 After ADFwPkg 2.17.0 - June 2011 4 Battery Holder New batteries = 6.2 VDC Low battery threshold is 4.7 VDC for SM & MT - and 3.7 VDC for MAG and PROX (USB stops working at 4...
    AD400/AD200/AD250 After ADFwPkg 2.17.0 - June 2011 8 Battery Holder New batteries = 12.4 VDC Low battery threshold is 7.2 VDC Critical battery threshold is 6.9 VDC Coin cell = new/...
CO2004 Battery Holder (ONLY) New batteries = 6.2 VDC Low battery threshold is 4.2 VDC Critical battery threshold is 3.9 VDC Coin cell = new/full is 3.0 VDC, low is 2.8 VDC
CO2504 Battery Holder (ONLY) New batteries = 6.2 VDC Low battery threshold is 4.2 VDC Critical battery threshold is 3.9 VDC Coin cell = new/full is 3.0 VDC, low is 2.8 VDC
  CO200 & CO250 Disable coin cell Nuisance delay and blink, With CO.A.7 and SUS 4.10.2 or newer for CO200 and CO250, you can use the SUS/HHD, under Lock Properties, Edit, to de-select, DISABLE, t...
Causes for AA battery drain in AD-Series LOCKS Possible Cause Fix/Corrective Action 1)      One the four (or eight) AA was inserted reversed and the rese...
All Schlage/XceedID wiegand proximity readers currently understand: -ASK (Amplitude Shift Key) - Used in GE/CASI -FSK (Frequency Shift Key) - Used in HID Prox, AWID, and Lenel The third proximit...
ISOX card technology is no longer supported - contact XceedID sales
When the SUS and HHD are used in the “Auto Update” mode, the audit info will be automatically gathered each time the SUS is successfully connected with a lock.
During the rehanding of an AD-Series Exit (993) device or the rehanding of a CO-Series Exit (993) device it is possible for the customer to damage the 5-inch pcba by using the wrong screws.  D...