Von Duprin

Question
Answer
This is in regards to the California State Reference Code, (Formerly Title 19, California State Fire Marshal Standard) stating that all levers with returns comply; levers must return to within 1/2"...
All inquiries from a customer (Voice mail, Email, Call) regarding specific product information because of an incident, lawsuit or lawyer involvement please send information to Tracy Jaques, tr...
BAA/ARRA stand for Buy American Act and American Recovery and Reinvestment Act. A brief description of some of the federal requirements can be found in the BAA Catalog on the Allegion...
Country of Origin (COO) information can be found in the Buy American Act (BAA) brochure.
To obtain product certification forms:Download the BAA Catalog on the Allegion website Complete the information requested in the the BAA Catalog with a detailed copy of the prod...
The PS900 series of power suppllies replace the PS873Only the PS900 series is UL294 compliant. PS873 is not UL294 compliant. 
The PS861, PS873, or PS902 power supply can be used to operate the Von Duprin E996L trim.
The Von Duprin E996L trim required .22 amps at 24VDC.
Von duprin will supply the 996L and 996L-BE trims with RX switch. Von Duprin will not supply the 996L-NL and 996L-DT trims with RX switch because the switch monitors the lever movement and the leve...
The 9975 mortise device requires a 996L-M trim.
The 909 strike is used in single and paired non-fire rated and single fire rated openings.  The 954 strike is used in fire rated paired openings.
The 1609 strike cannot be used with Von Duprin XP98/99 exit device.
See attached instruction for re-handing the 996L/E996L trim.     Click Here: Trim Re-Handing   See page 2.
To change the function from TL to NL on 360L trim, invert the cam on the mortise cylinder.  See attached instruction 360L trim instruction.
To convert the E360L electric trim from fail safe to fail secure or vice versa you need to replace the solenoid.  The 050743 is the fail secure and 050744 is the fail safe solenoid kit.  See atta...
We do not offer the 230L with night latch function. There is no conversion available.
The 388 Cylinder Control is required for the NL-OP function on a 33A/35A series exit devices. The 110NL is used on 22 and 98/99 series exit devices not 33/35A series devices.
Both E7500 mortise lock and E996L-M provide electrical control of the outside trim.  The E7500 mortise lock offers two monitoring switches that would not be available on the E996L-M trim. They moni...
The VD 7308/7311/7321/7322 were replaced by the KP212 Von Duprin 7311 and 7321 key pads were discontinued and there are not direct replacements Von Duprin no longer sells key pads, contact Schl...
The E996L Conversion Kit is only used with 996L trim and will NOT work in a 994L or 992L.
We have several blank trims listed in the price book to cover existing trim prep in door.  DEVICE EO TRIM   22  230EO  88  880EO   98/99  990EO or 996EO*  33A/35A Rim, 33/3...
The 992 and the 996 trims use the same lift springs part number 971573 and there are 2 used in each lever trim.
In a push button type switch (RX or LX), in which the contacts remain in one state unless actuated, the contacts can either be normally open (abbreviated "n.o." or "no") until closed by o...
Use the standard 996L standard template; 20003 for metal door and W20003 for wood door.Click - template for wood doorClick - template for metal door
The Von Duprin CM993 Computer Managed  trim was used with 98/99 series exit device and is no longer available. There is not a direct replacement for CM993 trim. AD200/400-993 series are the clo...
Panic Hardware and Fire Exit Hardware are two different types of exit devices, and the proper selection is determined by code requirements. Panic Hardware is an exit device which is tested for u...
The most obvious difference (in the device) is the lack of mechanical dogging on a Fire Rated Device.  There are some internal parts that may be different and the method it is secured to the d...
All Von Duprin 98 and 99 trims include screws for both 1 3/4" and 2 1/4" thick doors.
Order E-Trim Mech Kit  part #050671-00 which will include a new solenoid already mounted to the blocking mechanism. See installation instruction # 921297 here which will show how to remove block...
Knurling not available on any pulls.
The only parts that are available for 34/58 for mortise lock bodies are: 091032 Aux Bolt Spring Pack of 10 091031 Dog Spring Pack of 10 091030 Thumb Spring Pack of 5
The 555NL cylinder assembly must be ordered.
The 376T trim activates and connects to the 33/3547A top rod. The 360T activate and mounts to the 33/3547A center case.
The minimum clear opening width for ADA is 32" measured from face of door opened to 90 degrees to face of stop on strike jamb. There must be no hardware mounted to the door projectin...
266M is on all Von Duprin exit devices and does not identify the device.
All Von Duprin 370 Series trims require a 1 1/4" mortise cylinder with a straight cam.
Changing the handing on a Von Duprin 373L trim requires following parts: LHR to RHR requires 090092 ( Package of 4 springs ) and 050597 ( back plate assembly ). RHR to LHR requires  090091 ( Pa...
It is normal for a solenoid to be warm to the touch.
Various situations, such as continuous duty use or application of voltage that is higher than specified, can cause the solenoid to become warm.
If there is concern that the solenoid or device is "too hot" or has the capability to cause injury, disconnect the device and contact a authorized service representative to analyze the opening.
Followings are the steps to convert the Von Duprin 88TP to 88L device. Need to replace the back plate on the 88 exit device, part number 050103. Order a 373L trim and specify handing. Recomme...
The 050672 is the part number for rim or vertical rod device and 050673 for the mortise device.
Due to design the latchbolt of a XP98/99 does not retract into the center case of the device from any trim input. Pushing the pushpad or using the exterior trim allows the latchbolt to "pivot" arou...
360 auxiliary package contains: control tailpiece (972385), tail piece guide (971059), cylinder locknut (971974) and pine tree clip (971090).
The Schlage Longitude and Latitude levers are not compatible with the Von Duprin trims.
Attach is the instruction and template for 237L device, 237 Instructions.
The E conversion kit will work on any 996L trim.Part number is 050672 for the E conversion kit for Rim or Vertical rod trims and 050673 is for mortise lock trims.
You must have the Von Duprin NL Cylinder plate part number 967484-89 to convert the 370 series controls from classroom function to night latch function. If new installation, use the NL cylinde...
The BHMA standard 689 is an Aluminum finish, and is silver/gray in color.
For Hollow Metal door:  10301 and 20005For Wood Door:  W10301 and W20005
The new exit alarm ALK uses the 24VDC regulated PS902 power supply.
BHMA provides a certified products directory complete with function codes and meanings from most of the major lock manufacturers.  The most up-to-date directory can be accessed through th...
Frascio is a company that provides decorative lever sets for many of Allegion products.  More information can be found on their web site at WWW.frasciointernational.com.
Standard 996L trim fits from 1-3/4" door up to 2-1/4" door.
No longer available, the 334 cylinder control was for the old style 33/35 series exit devices which was discontinued in August 2003.
We ship the standard installation instructions because it contains enough information to show how to convert the trim from mechanical to electrical.
The Von Duprin 1609 cannot be used on a pair of fire rated doors. We recommend using the Von Duprin fire rated mortise exit device in lieu of the rim device such as the Von Duprin 5575-F,...
The 996EO trim is just the plate without the lever and cylinder hole
Recommend to order a new 990NL-R/V or M trim to change from TP/Classroom function to NL/Storeroom function. You will also need to reinstall the NL drive screw back into into the mast...
The Von Duprin 372L & 370L/BE series trims are discontinued and there are no replacement for them.  The new 33A/35A series exit devices use 360L trim. 370/BE trims were used with old style 33/35...
RX switch is request exit and LX switch is latch bolt monitor switch. They do not required a power supply directly. The electrified hardware that RX or LX switch conne...
The template for E996L wood template is the same as 996L wood template. W20003 for rim or vertical rod and W20006 for mortise.
The 376T is the correct thumbturn control for 33A/35A/98/9947/48 exit devices for metal door and 376T-WDC for wood door. 
The current 33/3547/47-F latches are the same as the latches used with the old style Von Duprin 33/3547/47-F devices. 
You will need the 050140-xx finished screw package to mount the trim to a wood door.
 Click Here to view the Hollow Metal or Wood Door Templates for Von Duprin devices   The E996L trim and RX98/99 devices  use the standard 996L and 98/99 templa...
Von Duprin 98/99 NL drive screw is located in back of the 98/99 center case assembly. NL drive screw should be left in with trim lock slide plate in up position in the 98/99 exit device with E99...
If the NL screw on the 99 device has been removed the Trilogy lock will not retract the latch.
The following items may cause the exit devices top latch from being held in the retracted position. 1. The top or bottom rods are out of adjustment. 2. The top latch hold back...
Following exit devices 2227/F, 33/3527A/F, 33/3547A/48A/F, 98/9927/F and 98/9947/48/F have similar rod adjustment procedures. All top latches control the bottom latch assemblies. When do...
If the RX switch is in the device itself yes. You can not however have both the "E" and "RX" options in the same 996L trim as both the solenoid & switch are mounted in the same place in the trim.
Part number for the 373L spindle is #967480-89
We used to offer a E99 rim device where there was a solenoid to lock or unlock the lever or thumbpiece trim on the back side of the center case of the 98/99 device.  When we created the E996L trim ...
To order Von Duprin exit device reference the "Additional information/How to order" section in the Von Duprin catalogs. All Von Duprin device series Catalogs are available on website.
Existing Von Duprin LP373L-BE trim can't be electrified. You can order an E-LP373L-BE trim. LP373L-BE or E-LP373L-BE trim is used with Von Duprin 94/95 series Inpact devices.
Standard E996L operates on 24VDC and 250 milliamps.  If AC power is applied this could cause the E996L to "chatter".  Possible Solutions:Check your voltage. Make sure the wires on th...
The amp draw on EL device is16 amp inrush with .3 amp holding.
The 4 main mounting studs are located in the same position, but the 990 trims have a 5th stud located at the bottom of the pull handle.
Von Duprin does not offer any of the danmark lever designs by Schlage.
No. The handed baseplate must be purchased:KIT.1011 EL1490 Conversion Kit LHR 36" - KIT.1010 EL1490 Conversion Kit RHR 36" - KIT.1013 EL1490 Conversion Kit LHR 48" - KIT.1012 EL1490 Conversion K...
We no longer carry trims for the old style 33/35 exit devices.  New trims for 33A/35A series exit devices will not work with the old 33/35 series exit devices.
E option for 98/9975 is an electric mortise lock.E7500 and E996L is an electric trim.
The Von Duprin 994L series trims were square on top and bottom.  They were discontinued in July 2010.
A standard exit device can't be modified to a fire rated exit device.  A new device must be purchased.
E996 trim can be ordered FS or FSE, lever trim must be either L or L-BE. In both situation (E996L or E996L-BE), the electronics lock/unlock the lever. The E996L trim allows for the inst...
This is usually an indicator of applying excessive voltage.  Measure the voltage going into the solenoid and make sure you have 24-26.4VDC cross the two wires going into the solenoid. Also measure ...
The attached table shows the part numbers for LX-RX and LX-RX-LC switches field installed.
There is not a conversion kit to electrify the LP373L lever control.  You need to order a complete E-LP373L-BE control through Engineering Specials.
The 98/99 series tailpiece guides part number is 050156-00, package of 10.
PS902 is a 2 amp power supply and each E996L electric trim draws 0.25 amps at 24VDC. You can have up to eight E996L electric trim per PS902 power supply.
To find 338 strike location in frame you must follow the backset information on device template. This strike is used with multiple devices and has many dfferent backsets, depending on device.
The 237L can't be used as a LBR on fire or non fire rated openings
The Von Duprin 98/99EO exit devices will accept any of the exterior trims that we offer for 98/99 exit devices without any extra parts. 996L, 996L-NL, 996L-DT, 996L-BE, 990NL, 990DT, and 110NL a...
The conversion kit does not contain a new mechanism case cover plate.  If a cover plate is desired you would need the Fire or Less Dogging Cover Plate for EL conversion kit and panic cover plate fo...
Electric locking is not available on 98/99 rim device.  This option is available on the E996L trim with all 98/99 rim, mortise, surface and concealed vertical rod devices.
Yes, Von Duprin 996L lever handle can be replaced with a new one . Attached installation instructions shown how to replace the existing lever handle on 994/996L trim for rim and vertical rod device...
The part number for the 230L trim shear pin is 050148 (pkg of 10).
To use 350 dummy push bar with 996L-DT you will need the 050140 mounting hardware for standard 1 3/4" door, or 050141 for 2 1/4" door.
Cylinder dogging (CD) and an RX switch can be ordered together with 33/35 or 98/99 series.
This can be done ONLY with non fire rated exit devices.
Check the voltage at the strike and make sure you have proper voltage at the strike. 
AutoCAD drawings are proprietary and are not available for distribution.  One option are BIM objects which are available.Allegion now has BIM objects available for the LCN®, Schlage®, Ste...
The UL fire label is only applied to the device center case cover at the factory when the device is built.  This label can not be sold or replaced with a new one.
The Von Duprin Chexit-BOCA has special software. Following is the function of this software: When Chexit device push bar is pushed and goes into alarm it will release in 15/30 sec...
Changing the handing on a Von Duprin 373L trim requires following parts on all lever designs EXCEPT #12: RHR requires part number 090092-00 (LEVER CONTROL SPRING RHR PKG/4) and 050597-...
The Von Duprin 7500 mortise lock body will replace the old style 34 and 58 lock bodies. Order a 7500 mortise lock in the proper finish. The old style strike must be replaced with 575 strike becau...
You must order a new 996L-NL-M trim.
This solenoid is replaceable and the part number is 050671.
The E371L-BE trim can be use with 5547-F device.
AFL stands for "Auxiliary Fire Latch" on fire rated exit devices.
NLOP means Night latch optional pull (night latch cylinder assembly with pull by others).
Von Duprin used to offer a KP992L trim that was operating the 98/99 series exit devices but it was discontinued in mid 1990.  Von Duprin does not make a keypad trim any longer.
The only electric trim that is used with the 98/99 series exit device that Von Duprin offers is E996L lever trim.
E996L electric trim is used to lock or unlock the lever trim for the 98/99 series exit devices.
 A Von Duprin EL device can have pull side key access in cases of power loss when used with a trim with key over-ride to allow entry.
The Von Duprin 230L trim can be re-handed in the field by following the steps listed in the 230L/L-BE Instructions
Exit alarm ALK devices are not recommended for exterior application. We do not offer water proof exit alarm ALK devices.
Please see the Maintenance Kit Manual for information on device lubrication as well as complete breakdowns and parts lists for Von Duprin exit devices.Exit devices and latc...
The 996L-NL R/V trim is the same for rim, surface and concealed exit devices so this will work.
The Schlage Danmark levers are not available on the Von Duprin 996L lever trim.
The 248L-4 strike is not fire rated and can't be used with fire rated device.
Part numbers available here.  A, B, C dimensions also shown in this document.
Reference the field handing section on page 2 of the 996L-R/V installation instruction.
The 210K trim can't be converted to NL function.
Changing the hands is not an option.  Recommendation is to replace the E376L trim with the correct handing.
The 576A or 576B strikes can be used on wood doors but you should check with door manufacturer if it is a fire-rated door to make sure there are no conflicts.
The 98/99 rim and vertical rod exit devices are shipped with NL drive screw to function as a Night Latch. To convert the device to Class Room, remove the NL Drive Screw on 98/99 center case ass...
The Von Duprin 370 series control required a 1 1/4" mortise cylinder and will not operate with 1 1/8" mortise cylinder.
Custom Wiring Diagrams When common wiring diagrams do not meet the needs of the job requirements, Allegion offers a service to purchase custom wiring diagrams.  All custom wiring diagrams inc...
Request Form Located Here
Von Duprin doesn't offer an exit device that provides deadbolt.
The existing 373L control was modified and re-named as 379L to allow us to use the 55 rim device on an ADA door opening.  The 379L control is our 373L with different hex st...
The Von Duprin E996L electric trim is field reversible. See attached 996L installation instructions on page 2 for rehanding procedure.  996L Installation Instructions
The devices baseplates/scissor assemblies are different and will not accept the Von Duprin RX switch.
The 994L and 996L trims are both Break Away style levers standard.
You can only use one GBK Glass Bead Kit (1/4") per device on fire rated openings. Glass Bead Kit is for use on doors with raised glass beads.
The E996L-FS fail safe trim works as a mechanical device when there is no power applied to it. Key cylinder will not lock the lever. Lever will be always active.The E996L-FSE fail secure ...
Von Duprin 98/9975EO exit device will accept any appropriate trims such as the 996L-M, 990NL-M or 990TP-M.
Device: Pushbar end caps, pushbar trim and center case cover. Trim: Lever assembly, trim plate assembly (trim plate and bushing sleeve).Bronze Finish Comparison
When you order the 98/99NL-OP the 110 cylinder assembly will be provided.
The 230L trim will cover a 160 prep but only on non fire rated doors.
Use the 050144 mounting package for 1 3/4" door thickness.
If the spring on the Von Duprin exit alarm ALK board is not located correctly as shown on the instructions, then the vibration from the horn allows the cylinder to turn and shut the exit alarm ALK ...
There is not a wood template for 9957 three point latches, use the 98/99 rim template W10301 to get the correct device backset.  For NL trim (990NL) use trim template and installation instruction W...
A 1 1/4" mortise cylinder with straight cam (similar to the Schlage B502-191) or a 1 1/2" mortise cylinder with straight cam using supplied spacer collar. Cylinder length does not chan...
L-NL is rigid lever with key override, also called night latch function.
There is not a direct replacement for the old Von Duprin 700 Shear Lock series mag lock.The Von Duprin 700 had been replaced by the old Locknetics 280-700, which has also since been discontinued, a...
There is no template for 996L-DT for wood door. You will need to use the 996L-DT installation instruction or 996L-DT metal template. See attached instruction/template 996L-DT instruction/template.
Solenoid for the older E992L is not available even via Engineering as a Special. The E992L trim was discontinued in August 2005 when the E996L trim was introduced. The current E996L solenoid i...
There is not enough room to have an electric solenoid and cylinder on an E371-LBE narrow style trim.
Strike or ridged plate with ridges part number is 970323622.
Von Duprin does not supply cylinders keyed alike.   Cylinders keyed alike are available from Schlage and Falcon.
The 893P is not a strike, it is the UL label on a 6000 series strike.  This label will not describe the strike you have.
Night Latch (NL)= key retracts the latch momentarily to allow entry. When key is removed, the latch will extend and locks the door (momentary unlock). Class Room (Lock/ Unlock)= key unlocks...
The 996L trim will cover the 161 prep.
Tactical Warning is a surface texturing (can be knurling, abrasive strip or etching) treatment applied to lock and exit device trim as a warning (particularly for blind people) that the door open...
Von Duprin warrants that the product manufactured by it and delivered here under will be free of defects in material and workmanship for a period as follows: Exit devices and trim for 36 months...
The Von Duprin 210L trim is no longer available and was replaced with the 230L trim.
Not a true NL function where the key retracts the latches, but an NL function can be achieved by using the LP374L lever trim in an "NL" function.  The lever will only unlock while the key is t...
The Von Duprin RX996L trim was released to standard order entry in May 2010. The Von Duprin 996L and 996L-BE trims can be ordered with RX switch. The 996L-NL and 996L-DT trims can not have the...
The part number for the cable or wiring harness for an E996L trim is CABLE.10038
You can't make the EL device quieter but you could convert to a QEL device with appropriate PS873-2Q or PS900-2Q power supply.
The 550DT pull handle trim is used on the 5575NL.
The LX switch monitors whether the latchbolt is extended or retracted.
The wires run through the device out to the EPT. See step 7 on page 5 of E996L instructions.
The part number for 499F hook is 661481-32.
The newer rods have a "stair step" that allows the use of the newer 996L lever trim.  If needed the bottom rod on the 98/9947 must also be replaced, part number 050575-00. 
You can't see the 110NL cylinder assembly from the pull side. The only thing that is visible is cylinder and cylinder color.
The 388 cylinder control less pull is used when ordering 33A-NLOP.
The 360L control can be field configured for either Classroom or Night Latch function by inverting the cam on the mortise cylinder. If the 360L functioning in a NL mode and you want classroom, inve...
These are available:050672 is the part number for for Rim/Vertical trims050673 is the part number for Mortise trims
If the green terminal block has been broken off of the exit alarm ALK you must replace the exit alarm ALK PC board part number 101030-00.
Optional knurled levers are available on 03 and 06 lever designs as a standard.
No, the exit alarm ALK printed circuit board has been always green.
The part number for Von Duprin exit alarm ALK board is 101030-00.
Von Duprin discontinued selling mag locks in the early 1990's.
1400 degrees which is approximately 20 minutes after the fire starts.
996L trim is a standard Classroom Function lever set for the 98/99 panic devices.  The 996L-NL trim is a rigid lever for the 98/99 device where the key will retract the latch on the panic device bu...
This is not an available option, a device can either be a standard EL or a QEL but not both.
The 697 can be purchased and then swapped in the field or it can be ordered as an Engineering Special.
A cylinder assembly consisting of a cylinder collar, cup and screw.
The templates are the same for both EL and QEL devices.
The 7500 mortise lock body is the same as it was when developed.  The same 7500 is used with the 98/99, 88, 55 and CX devices.
EL is Electric latch retraction and retract the latch bolt into the exit device center case.  E references the electric unlocking of the Pull Side trim for a Panic Device.   With the E function, th...
Application is based on how the door will be used.   Please contact Product Support at 877-671-7011 to discuss your application and select the correct device for your opening.
The Von Duprin “Safety Glow” coating is a specially designed powder coat finish that glows brightly during low or no light conditions. This coating was developed to meet MEA standards where lumines...
The 880 series trim will work with the 44 series device.
Calibration is an internal process of the QEL device when energized the 1st time.  The solenoid will pull and drop 3 times on a standard calibration.  Calibration can be forced by pr...
The operation of the 230L can not be changed.  You will need to use the 210NL trim that has the same mounting with the addition of a cylinder hole
The 375L is the only lever trim with 5575 mortise device that locks or unlocks the outside handle.
The 909 strike is used in single and paired non-fire rated and single fire rated openings.  The 954 strike is used on fire rated pairs with mullion. The 299 and 1609 strikes cannot b...
You cannot lock the push side of the exit device as a panic device by design must allow exit.  Any attempt to block an exit is forbidden by code.
HD-EL Plunger part number is 050537.HD-EL Solenoid part number is 050536.
 The key on the trim is a NL function as a standard.
PBKIT.1043 Or ordered as PBKIT 98 3' US32D SS PBT.
The part number for 2670 cylinder tail piece extension is 050379.
Von Duprin doesn't have any weather proof electric products.
We do not recommend as Fire rated devices are always latched and they would not be able to unlock and pull the door open.
No special required, cut the length of the tailpiece for 2 1/4" thick door per installation instructions.
A PBKIT is a Pushbar Retrofit Kit.The pushbar retrofit kits are not the same for 33A/35A and 98/99 series exit devices.  Depending on the finish of the exit device, the pushbar end caps are di...
Assuming everything else on device is functioning normally ie; audible, 15 second delay, External Inhibit input, FA input, DPS input then LED on circuit board is bad.  The Chexit mod...
The EL solenoid for the device is only 24VDC which must be provided by a Von Duprin PS873-2 or PS914-2RS/4RL power supply.
FS- Fail Safe unlocks without power.FSE - Fail Secure locks without power.
Only the 02, 03, 06, and 17 levers on 360L, 370L, and 996L series trims are available in knurled. Von Duprin doesn't offer Teflon coating.
Von Duprin doesn't offer an exit device that would mount to a frameless glass door. Usually the glass manufacturer would mount a mounting plate to the glass for the exit device to be attached to th...
Products shipped on or after August 8, 2012 no longer require the EL wiring adaptor.
  The part number for EL wiring adaptor is 44486876-00.  The part number contains two adaptors.
 Cam Lift Hinges are specially designed hinges used mainly on acoustical door assemblies. The Cam Lift Hinge lifts the door during its travel and seats the door bottom for a pos...
Position the 379L  trim and attach with countersunk screw into the bottom stud of the trim.  Position the 55 Rim device and attach with the device mounting screw through the head of th...
The 230L trim can't be set to L-NL function.
To change the 360L from TL (classroom) to NL (Night Latch) function invert the cam on the mortise cylinder. See attached instruction. 360L Instruction
The RX-LC and LX-LC (Low Current) switches are used for current up to 0.05 amps at 24 VDC and the standard RX and LX switches are used for current greater than 0.05 amps up to 0.5 amps at 24 VDC.
LXRX switches are one complete assembly together with EL device. Existing RX switch must be removed from device and install the new LXRX switch assembly into the EL device, part number 050259-00.
The part number for the E996L 24VDC solenoid only is 050814.  The 12VDC solenoid is available only as an engineering special.The solenoid and slide bracket assembly part number is 050671.The E...
The PS914-4RL replaced the PS873-AO power supply. Program the 900-4RL board for AO function per installation instructions.
The E996L trim wires run through the exit device and out near the hinges.  
The best way to test the Von Duprin EL solenoid is with an ohm meter. You must test both coils to make sure the solenoid is good. The coil has three wires; green, yellow, and orange. The green...
The RGO (rod guard only) is 36" long x 1-5/8" wide.
The UBC (Uniform Building Code) was a regional legacy building code which was superseded in most jurisdictions by the IBC (International Building Code). There may be some areas of the country which...
The plate is 1-5/8" wide by 8 3/4" long x 3/16" thick.The knob has a 2 1/4" diameter and a projection of 2 3/4"
This is not possible. A 3 feet EL conversion kit can only be used on a 3 feet device with a 18" push pad.  Also a 4 feet EL conversion kit can only be used on a 4 feet device with a 24" push pad.
Equivalent to the Schlage D series line with a C keyway. Part number 21-002.
The old MPB842 power supply will power up to two EL electric panic bars but will not power the QEL devices.  A defective potted module inside the electric panic bar or defective power supply coul...
Hardware falling off a door is caused by one or all of the following issues: Field abuse Improper internal reinforcements in the door Improper field preparation The top or bottom rod case can...
The Schlage King Cobra locks and trims are no longer made. Use the AD and CO series electronic trim specifically made for our 98/99 series products.
The 050105-00 conversion kit and 110MD for metal door or 110WD for wood door.
Use NL cylinder plate, part number 050599-00. See attached drawing for parts 376T Control NL/TL conversion.
A standard rim cylinder per 110 Installation Instructions.
The 230L mounting stud is part #971245.
Von Duprin parts manuals are downloadable on the US.Allegion.com document library page.In the filter, select:Document Type: ManualBrand: Von DuprinCategory: Exit DevicesThis will pr...
Von Duprin Exit Devices (33A/35A, 98/99, etc) are handled on a case by case basis regarding their ability to handle salt and chemical environments. Our powder coated finishes US28 (Anodized Alum...
The 996L trim is the same for 98/99 rim and 98/9927/47 devices.
Mullion Edging - 7'   = Part #965712Mullion Edging - 8'  =  Part #965713Mullion Edging - 10' = Part #965714
All extended warranty requests are handled by Allegion Warranty Service Team.  Email Requests to warranty.service.requests@allegion.com.   
Minimum wire gauge requirement for Von Duprin electric latch retraction is as follows: For Product Shipped Prior to August 2012 using the old (black) potted module: 0-100 ft 14 gauge wire 0-...
The Von Duprin 6300 strike will work with the Dor-O-Matic 2090 rim exit device.
CO993 trim with 98/99 rim device requires 4 9/16" minimum style with a 299 strike. If the trim required to be center on the stile it would require 4 3/4" minimum style.
If voltage going into the solenoid is much higher than 24VDC it could cause the solenoid to get hot. Check the power supply output voltage to confirm. If the holding coil on EL solenoid is shor...
The EL wiring adapter is not needed for QEL devices.
The regulator on the main PS873 circuit board has failed.  Replace the PS873 with PS914 power supply.
The CX (Chexit) is the delayed egress option for the 98/99 series or 33/35A rim device. The device will create a 15 second delay with audible alarm when an unauthorized person tries to ex...
The E373L-BE trim is an option.  You need to specify FS for fail safe or FSE for fail secure. There is no key override with this electric trim.
299 strike = Zinc 299F strike= Stainless steel
This application requires at least six wire hinge, two for RX, two for LX and two or four for EL device.  You will need an eight wire hinge and double up the EL wires.
Reference the 994L trim which has the same internal parts in the parts manual.990 Parts Manual
The electrified hinge can be used on QEL exit devices.
The power to the Von Duprin potted module also called potted circuit breaker is non polarized.
Followings could cause the PS914-2RS power supply to cycle on and off: Wrong gauge wire or run distance from power supply to the EL device. Click HERE for wiring requirements Over load  to the ...
The thumbturn on the 376T control always turns clockwise, not handed.
The 230L trim only operate as a class room and is not available with NL option.
The diameter cylinder cutout for the door for 990NL trim is 1-5/8" on the pull side of the door and 5/8" on the device side of the door.
Von Duprin offers the E360L-BE-FS or FSE-24VDC control trim for 33A/35A series exit devices. We also offer the 360T-BE and 376T-BE controls electrified. IE, E360T-BE or E376T-BE-FS or FSE...
The 237 device can not be used on wood doors. This device is only used on hollow metal or wide style aluminum doors up to 8 feet tall door standard.
Von Duprin offer a 55NL-OP. Specify 55NL less trim for wood or metal door, you will receive the 55 device with 110-MD or 110-WD control.
Some components are still available such as the lever, thumbturn, lever bushing, thumbturn bushing, lever springs and thumb turn spring.  Items such as the actuator assemblies for both 1 ...
See attached table: Schlage 692/672 Parts Cross ref
The sign for exit alarm, ALK, is SIGN-1.
The 237 device can't be used as LBR.
You cannot retract the 8827 rods and latches directly with a cylinder.  A 377T trim is required to activate the thumb turn of the trim with a cylinder so the thumb turn can activate the rods a...
The projection dimensions are different.  264 strike has 9/16" projection299 strike has 13/16" projectionAll other dimensions are the same
To add a cylinder to the 98/99-EO rim device order a 110NL-MD for metal door or 110NL-WD for wood door with a standard rim cylinder and prep the door per template.
The Von Duprin Guard-X exit device is not fire rated because the deadbolt is not spring loaded. Therefore, there would be no positive latching as required on a fire rated opening. 
A defective QEL motor assembly could cause the latch not to extend out fully when power is removed from the QEL motor.
There is not a chart that shows which sex bolts are required for Von Duprin or Falcon/Monarch exit devices.
Handing can be reversed, reference the 360L installation instructions.
The PS914 power can operate up to four Chexit devices and the E996L trim.
The 370L control was used on an old style 33/35 rim and surface vertical rod exit devices and is no longer available.
This is available, order the 990EO exit only trim plate.
The E996L is only shipped FS fail safe from the factory but can be converted to FSE fail secure.  To convert the 996L to E996L (fail safe or fail secure) follow step 1 of the attached installa...
A E996 conversion kit is required to convert the 996L/L-BE trim to E996L/L-BE electric trim. 050672-00 is the electric conversion kit for 996L rim or vertical rod exit device. 050673-00 is the ...
The cylinder spacer collar is the only part that is different between the Von Duprin 556WD-NL cylinder assembly for 1 3/4" door and 2 1/4" door. Cylinder spacer collar part number for 1 3...
There is no 230L-NL trim available.  Suggest to use the 210NL or 230NL trim.
ELECTRIC OPTIONS: LX (Latchbolt Monitor Switch) – The LX feature is used to signal the use of an opening. This device is equipped with one internal SPDT switch which monitors the latch bolt. ...
RX (request exit) switch monitors the pushbar and DPS (door position switch) monitors the door status.
The 33/35 devices where discontinued in 2003.
The 900-2Q board is no longer available. For warranty purposes, QEL conversion kit and 900-2RS board are required. The 900-2RS replaces the 900-2Q board.
You can use the E996L electric trim with Chexit 98/99 series exit device.
The new QEL motor has a label affixed to the cover, the older QEL motor has no such label.  See attached image.
The use of Panic Hardware and/or Fire Exit Hardware is required by the International Building Code (IBC) and NFPA 101 – The Life Safety Code, depending on which code and which edition of the code i...
Clear Opening Width for swinging doors is measured (with the door open 90 degree) from the face of door to stop soffit on strike jamb.          &nbs...
You can use the new QEL+ device with 900-2Q option board.
The new potted module (PWM) has a built in LED that will show through the protective encapsulation.  Orange LED flashes briefly upon applying power to the EL device but does not stay on while ...
The new potted module ( PWM ) operates with a soft start, gradually increasing the input on time to the pull coil until it is on 100% of the time. This results in less noise when EL solenoid is pul...
You can order the EL and E trim in the same device. EXAMPLE: EL98/99 with E996L trim.
Invert the cam on the Mortise cylinder per step 1and 2 of the installation instructions.
Delayed egress hardware prevents a door from being opened from the egress side, usually for a period of 15 seconds. This type of device is often used to prevent theft, while maintaining life safety...
A Mullion is a vertical frame member set in a double door opening which will allow both door leaves to be active. Mullions can be fixed or removable. Mullions may also occur between a door a...
The new PWM is NOT attached to the devise but rather shipped in a separate box within the devise carton.  This change was made to improve shipping quality by helping reduce wire damage during ...
That is the E996 Solenoid.  It is sold as part 050814-00.To replace the solenoid, refer to the E996L Installation instructions.The trim must be removed from the door.Verify if the tr...
If a vertical rod device, verify the vertical rods are adjusted properly and there is not a bind at the strikes.  Make sure the push bar is not binding at the pushbar guides or any other ...
The 880TP can not be electrified.
Wiring and Riser diagrams can be accessed at:Common wiring diagrams can be accessed at:  http://kc.allegion.com/.   Click on the "Common Wiring Diagram" link.To request a custom wiri...
AD and CO series -993-R model locks will work with most Von Duprin 98/99 series model push bars exit devices – Rim, CVC - Concealed Vertical Cable or CVR - Concealed Vertical Rod AD Series -200/250...
MultiPoint locks are three-point locking systems that secure the door at three points – top, bottom, and traditional center latch location. Operating just like traditional locks, MultiPoint locks a...
050815-00 FS Solenoid Assy Kit LHR050816-00 FSE Solenoid Assy Kit RHR050817-00 FS Solenoid Assy Kit RHR050818-00 FSE Solenoid Assy Kit LHR
The 940L trim is not available electrified at this time.
Schlage and Von Duprin introduced the new M Collection of decorative levers in January 2014.Click here to visit the new webpage.
You can view and subscribe to the channels below. LCN  Schlage  Steelcraft  VonDuprin  Falcon
Contact you local authorized Allegion Distributor for all Allegion brand logo information.
The Von Duprin AX was born out of a need to provide the market with a solution that meets recent California Building Code enhancements. Beginning in January 2014, the California Building Code (Chap...
Product AvailabilityIntroduced May 2014:Rim Devices – 22, 22-F, 33A/35A, 98/99, 98/99-FCVC-LBL Devices – 33/3549A-LBL, 33/3549A-LBL-F, 98/9949-LBL, 98/9949LBL-F Available starting mid-December 201...
HOW TO ORDER1. Specify CON for the Allegion Connector electronic options    Example: EL-99-EO-CON, (99 Series Electrified Latching exit only with Allegion Connect)    Example: L...
The American National Standards Institute (ANSI) and Builders Hardware Manufacturers Association (BHMA) have developed durability, strength and performance standards for every type of door hardware...
The most common cause is the position of the master cam on the 94/9547 or 94/9575 is not in the neutral position.  To change the position of the cam:Remove set screwRotate cam to neutral posit...
Backset dimensions will vary depending on the device, application and the opening configuration. If you have questions on specific device backsets, please e-mail your request (including a descripti...
These part numbers are not sellable part numbers. Order part 050535-00 for part 971687.Order part 050534-00 for part 110741.
Electric Power Transfer (EPT) provides a means of transferring electrical power from a door frame to the edge of a swinging door. The units are completely concealed when the door is in the clo...
The Schlage LM9200 Series is an innovative one or two point latch solution for pairs of wood doors where both leaves need to be active. Instead of traditional concealed rods, the LM9200 utilizes co...
 All parts (lock, door, rods, frame) must be ordered from Allegion as a package.  Thus you can not “mix and match” with other manufacturers.
The Von Duprin wood door concealed (50WDC) latching system is available on the 98/99 and 33/35A Series for use where fire and life safety codes require a panic or fire rated exit device.Unique cabl...
The E9975 uses the E7500 mortise lock, instruction sheet located here.  Includes wiring information
Please contact the Allegion Product Support Team on all questions or inquiries pertaining to hardware finishes warranties. Please send an e-mail to the applicable Product Support team:Closers_TechP...
UL listings can be searched at UL.com under Online Certifications Directory.
To install a 249 strike on a frame prepped for the 338 strike you will need to order a 338 filler plate, part number 24230914.  The 338 filler plate has mounting holes for the 249 strike.
The programming processes for Allegion devices can be both product and features specific.  Some products programming processes are electronic in nature, others are physical in nature. &nbs...
The thumbturn must be used every time to retract the latch.
Governments around the world are focusing on restricting and eliminating the presence of hazardous materials in products and packaging from the environment to improve the sustainability of our plan...
For information on the American Iron and Steel requirements, please contact material.declaration@allegion.com.
The 24-R can be used with the Von Duprin 6111 electric strike.
The Allegion Connect Connector Kit does not include a crimping tool.  It can be purchased from companies that carry wiring supplies.  It is Molex part number 63819-0000.The Allegion Conne...
Although Schlage recommends using mild soap and water for cleaning the finishes on locks, a list of common hospital cleaning agents and their possible effects on anti-mocrobial finish can be found&...
No, the latch can't be retracted because the Chexit solenoid is holding the latch in place.Since the cam is directly connected to the latch, it cannot be rotated.If an AD or CO were used, and the l...
No.As of 2016, these special modules are no longer available as replacements for EL Chexit devices.The device will need to be replaced with the new Chexit device, which can then be specified with...
Yes, from the device to the door side of the power transfer.Use the CON-6W on the frame side to connect with 12AWG or 14 AWG field wiring.  
Price Books are not available for public viewing. Please contact your local sales representative or distributor for price request.
1. SO rectifiers are only recommended with fail secure electric strikes for momentary unlock.2. SO12 requires 12VAC input +/- %10, and SO24 requires 24VACinput +/- %10.3. The output of the SO ...
It is not possible to add the DS switch option to a 6100 or 6200 series electric strike in the field.  It must be factory installed.  The DS switch assembly for the 6100/6200 se...
See link here.
Instructions 941335-00 explain the conversion from FS to FSE. You can find this document at us.allegion.com.  Go to Document Library and search for 941335.
The 6111 Electric strike will work with LBR options and Pullman Latch.
NO.  ES6400 power requirement is as follows. 12 VDC @ Continuous Duty @ .375 Amps*24 VDC @ Continuous Duty @ .190 Amps*12-24 VAC Intermittent Duty @ .280-.565 Amps** Ratings based on max ...
Yes, you can convert a standard Von Duprin steel mullion to a keyed removable mullion. (Aluminum mullions do not have a keyed removable option.)To convert a 1654 or 4954 - you need a KR54 kit....
Mullions are for double doors.  There is not a single door prep for mullions.
FOR RIM, VERTICAL ROD, AND VERTICAL CABLE DEVICES: The Chexit must be disarmed before a trim key, thumbpiece, knob, thumbturn, or lever (including electric lever) can be operated (rotated)....
Please review this application with Product Support.  This can be quoted through engineering specials.
An option board is not used.  The Chexit can be wired directly to its power supply.    The required power supply is different depending if the Chexit is using the older EL solen...
Von Duprin Rod Guards (RGO's) can be used on Falcon 24-V, 25-V, 19-V, and XX-V devices.They cannot be used on WS98/9927 or WS98/9957 devices.
Yes, the RX switch would need to be removed, and the E996L-R&V or E996L-M conversion kit would need to be added.
No.The strike is shipped with 2 standard faceplates,  and strike opening inserts,  for multiple mortise lock and cylindrical lock applications.
The Von Duprin® QM option controls motion to reduce operational noise.It is available for the 996 trim, as well as 98/99 and 33A/35A rim and surface vertical rod devices.The QM trim solution provid...
Accepting orders for the QM option on 98/99 Rim Exit Devices, 33A/35A Rim Exit Devices, and 996L/L-BE-R/V Trims starting 4/23/2018.Accepting orders for the QM option on the 98/9927 Surface Vertical...
The 6300 electric strike can be used on both side of a panic rated electrified steel mullion ordered without normal strike prep (ex. 4854 Blank).The 6300 electric stri...
No. The power wires to the QEL are not polarized
The 6300 electric strike is only fire rated (UL10C, 3 hour) for single door applications.For non-fire rated openings, a pair of 6300 strikes can be used on a Von Duprin steel (not aluminum) mullion...
The package number is 106183.  It includes a 4' cable that feeds through the exit device.  One end has a receptacle to connect to the E996 solenoid wire plug.  The oth...
They are compatible.  The center line of the MA latch bolt should be lined up with the center line of 6223 strike.  Another way to look at it is, CL of the MA lock body is ¼”above the C...
The QM option reduces the operational noise of the Exit Device or Trim during normal operation.Other factors can cause the complete door system to make noise. To be most effective, combine the Q...
A 9847WDC-F LBR or 9947WDC-F LBR device must use the 338 strike to maintain its fire rating.Using a 283 Strike in a wood frame would void the Fire Exit Hardware UL label of the 98/9947WDC-F LBR dev...
Check the condition of the LED on the motor.The Von Duprin QEL motor has a couple features that protect the motor.If the LED is alternating between Green and Red;There is a Tamper Resistance featur...
There is currently no Von Duprin electric strike with deadbolt monitoring.  The 6216 has a pocket for a deadbolt, but the monitoring switches available for that strike are only for monitoring ...
Part# 040192-00,  when ordering separately,  is the same as the Chexit  motor cable kit and the blocking device cable referenced in the Chexit installation instruction.
Please contact Cal-Royal for information on their Cal-Royal 5000EO / F5000EO Rim Push Bar Exit Panic Device. Von Duprin does not have a 5000 series device.
Order 650389-00 for the 18 V device.  
There is no easy way of releasing a stuck latch.  Beware that damage to door and or lock may be needed to free up door.  It is VERY important to follow the installation instructions and e...
Yes.  See the Chexit instructions,  or contact Allegion technical support,  for assistance with using a card reader (or other access control system)  with Chexit.
The 99-2 double cylinder was around long before the 996L was introduced, and it will work with the 992 and 994 trim.
No, the  pullman latch does not have deadlatching.
All 6000 series electric strikes are shipped with solenoids that require DC power.  Rectifier kits can be ordered to convert AC (from your power source) to DC.  Rectifier kit part numbers...
WHEN CONVERTING FROM STANDARD TO DOUBLE CYLINDER 98/9975 PANIC OR FIRE DEVICE, IT IS BEST TO REPLACE THE COMPLETE DEVICE. IF PARTS ONLY ARE ORDERED, THE CENTER CASE COVER WILL SHIP WITH NO UL PANI...
The 98/9927 latches made today can be used on the old 90027, however the cover plate does not have the correct rounded hole to accommodate the round rod of the older device.
You could use:Falcon: 25 R 512NL,  or Von Duprin: 98NL 990.
Yes, the 940L is backwards compatible with all 94 and 95 series exit devices.  The master cam on the back of the exit device should be positioned so the half-moon cut out faces toward the lock...
A new QEL baseplate assembly is needed.  The modular conversion kit needs the dogging rod to work.  The EL baseplate being replaced does not have a dogging rod.  
Standard Von Duprin LX switch kits are not compatible with the XP98/99 device.The LX switch in an XP device is mounted in the center case.  It monitors the position of the rear portion of the ...
The standard crossbar is 42" which will accommodate up to a 4' door.  For narrower doors, the crossbar is field cut as needed.
No, the Chexit center case is not sellable because the Chexit center case is integrated with the baseplate assembly due to the blocking mechanism.  If the center case must be replaced, the ent...
No, the Guard X allows for egress but is considered an "alarm lock" and not a "re-latching" exit device.  The latchbolt is only activated by key cylinder function to "arm/disarm" the unit.&nbs...
The 996L uses a Truarc 5160-42 retaining ring, sold as a package of ten under part number PKGSRV.1013.  The pliers that can be used to remove the retaining ring are Rotor Clip model RP204.&nbs...
The Trim/Device Cable part number is 040193.  If a Chexit device is ordered with an E996/RX996/E7500 from the factory, the trim/device cable is automatically furnished at no additional ch...
The Steelcraft Paladin Series doors and frames are available in compliance with FEMA 361 and ANSI ICC500-2014.  The door system may include other approved Allegion hardware and components that...
Yes, fire rated exit devices can have electric latch retraction.  However, the devices must be tied into a fire alarm system to remove power from the units so the doors will be latched in the ...
Yes, the Von Duprin ALK kit can be operated with either the 9 volt battery (supplied) or with 24 volts DC hardwired to the circuit board. 
The 994/996 lever trims have bulkier parts than the obsolete 992 lever trim.  When the 994/996 lever trims were introduced, the bottom rod for the 98/9947 was modified with a 3/8" offset to al...
Anti-microbial coating on top of powder coat finishes such as 313, 315, and SP28 has not been successfully tested and is not offered.
Yes, the PS914 (with option board) is compatible with QEL devices.  It will not "fry" the QEL device.  The power supply will only put out the amperage that the load (motor) calls for.&nbs...
33/3547 INS-2 One longer ratchet release finger Two longer fingers to connect the center case to the vertical rods 33/3547 INS-4 One longer ratchet release finger Two longer fingers to connec...
No, but a rep can order the 35A Center Case Cover Plate (1.42") 050475 in the finishes desired to create one.
Order 2 rod guards per device if you want to cover the top and bottom rod.  The rod guard (RGO) is furnished in a 36" length.  For doors taller than 7', order additional rod guards.
No, the 98/9927F exit device must use a bottom rod to maintain the fire rating of the opening.
No, the new 33A/35A exit devices can be operated with the new 388 and 386 trim but this trim will NOT operate the old 33/35 devices.
Yes, the RX-2 option includes two (2) RX switches in the Von Duprin panic bar.  
The RX996 replacement switch is sold as an engineering special.  It is priced the same as the add for the RX option for 996L.  This is a replacement switch only.  It is not possible ...
RX-E996L lever trim is available through engineering specials.
For a 55L application, the cross-shaped spindle on the back of the 379L requires that the device be furnished as an NL function, not an EO function.  The trim spindle operates the NL cam in th...
Please contact Von Duprin technical support.The most common issue:If an RX is used to trigger a QEL,  the QEL will retract both the latch and the pushpad.  Because the pushpad is held dep...
Yes.  MS764 made by Sentrol
If the door is pulled hard enough, the Pullman spring latch may depress far enough to allow it to ride over the the closed lip of an electric strike.  Please contact Von Duprin support to...
What Von Duprin 98/99 device finish is preferred for harsh caustic chemical damage in exterior conditions?  We recommend any of our "powder coat" finishes for these conditions (US28, 313, and ...
What Von Duprin power supply is correct for the new Von Duprin Chexit device (as of 2016)?  The Von Duprin or Schlage PS902 is correct for ONE Von Duprin Chexit device.  The Von Duprin or...
What is the part number for the Von Duprin E996 solenoid?   Von Duprin uses the p/n 991342 on the solenoid from our manufacturer.  Von Duprin customer service uses p/n 050814 in our ...
Must be mounted 6" from finish floor because that is how product was tested for certification.If customer has questions about mounting fire latch differently than shown in instructions,  custo...
The back of the Von Duprin price book lists the price at $250 as of 2019.See price book for information needed and how to order.Contact technical product support for further information  at 87...
No, the auto operator has a relay rated for only 1 amp max.  The chexit needs 1.25 amps to work.  
Hex dogging can be added to an existing QEL device.  Either the HD-QEL Baseplate Conversion Kit or the HD-QEL Modular Conversion Kit can be used to add hex dogging.
Fire mullions are rated to 10' maximum opening height.Mullions sold as 10' 3"  allow additional material for field sizing based on the type of frame/opening.
A 98/9947 device with the INS-2 option (or a kit 051841-00 added later) will not allow use of a functional 996L/L-B/K/K-BE trim or a 990 trim of any kind (except 990EO).
Click any link below to watch a brief video answering common technical support questions.These videos are not intended to be comprehensive instructions; they are visual reference only for common qu...
Externally;The older solenoid driven Chexit device key cylinder for arming and disarming the Chexit feature is mounted through a red, rectangular windo so that the white Status light shines through...