What is a U-Factor?

The U-Factor, R-Value and K-Thermal Rating are measurements of thermal transmission through building products.

U-Factor: Overall co-efficient of heat transmission passage through a built-up panel section. Technically, it is heat transmission in BTU per hour per square foot per degree Fahrenheit of temperature difference from air to air for a complete panel sectional.

  • The lower the U-factor, the better the insulation).

R-Value: Thermal resistance is a measure of ability to retard heat flow. R is an expression of the total resistance to heat flow through a complete panel section or construction assembly. “R” represents a value of the thermal resistance, per hour per square foot of a typical panel section. The R-Factor is the numerical reciprocal of the U-factor.

  • The higher the R, the higher the insulating value.

K-Thermal Rating: Conductivity (K) is the amount of heat that passes through a homogenous material one inch thick and one square foot in area per hour. Values of K are expressed in BTU per hour (the lower the K, the higher the insulating value). The K unit is for a single component material one inch thick and one square foot in area. Therefore, it does not apply to a 1-3⁄4” thick door panel consisting of several materials. (Conductivity is not a method of measuring heat transmission through built up panels.)

DISCLAIMER:

INFORMATION PROVIDED THROUGH THIS SITE IS PROVIDED TO YOU AS IS WITHOUT ANY EXPRESS REPRESENTATIONS OR WARRANTIES OF ANY KIND, AND WE MAKE NO REPRESENTATION OR WARRANTY THAT THIS SITE(OR ANY INFORMATION PROVIDED IN RESPONSE TO YOUR INQUIRY), WILL BE ACCURATE, COMPLETE, OR ERROR-FREE.

YOU AGREE THAT YOU MUST EVALUATE ALL INFORMATION AND RESPONSES, AND THAT YOU BEAR ALL RISKS ASSOCIATED WITH, THE USE OF THIS SITE, INCLUDING ANY RELIANCE ON THE ACCURACY,COMPLETENESS, OR USEFULNESS OF ANY INFORMATION OR MATERIALS MADE AVAILABLE THROUGH THIS SITE.

Other users ask