What are the LCN Senior Swing error codes?

Here is an updated list of errors shown on keypad display of the Senior Swing control:

  • Er04 - Voltage Monitor was high during Opening hardware check.
  • Er05 - Master or slave CPU has oscillator running at a harmonic.
  • Er06 - Testing hardware just before opening door, voltage monitor is low when should be high.
  • Er07 - Testing hardware just before opening door, series enable is low when should be high.
  • Er08 - Informed slave we opening door, didn't see series enable go low.
  • Er09 - Voltage monitor low when should be high.
  • Er10 - Voltage monitor high when should be low.
  • Er11 - Master CPU fails to communicate with slave CPU on a regular basis.
  • Er12 - Companion CPU sees triac come on but master didn't indicate it was turning on a triac.
  • Er13 - Master CPU informs slave CPU that triac is going to turn on but slave never sees it turn on.
  • Er14 - Someone added a slave door to a setup that was already sized.
  • Er15 - Invalid interrupt in firmware isr.
  • Er16 - Master CPU tried to communicate multiple times with slave and failed.
  • Er17 - System unable to size a second time.

All error codes (except 06, and 14) indicate a defective control box that would need to be replaced. Depending on conditions, 06 and 14 also require the control box to be replaced.