I was able to ping and telnet (or otherwise communicate to) the handreader, but I cannot connect via the SchlageCommDiags utility
If you used the default installation, you can find the SchlageCommDaigs icon at:
Start -> All Programs -> Recognition Systems -> RSI .NET 2.0 DLL -> SchlageCommDiags.exe
If no modems are detected, you will see a pop-up message: "You don't have any modems installed"; just click 'OK' to get to the actual utility.
if you are unable to connect to a handreader or fingerkey, please check the following: - Reader Type: select Fingerprint Reader if youhave any of the Fingerkey models (DX2000, DX2100, DX2200) or select Hand Reader if you have any of the Handpunch or Handkey models - select the tab that matches your communication method: if you select ethernet, please make sure the Reader Address in the next section below, is set to "0" (zero) - for the Reader Address, enter the same number that is programmed in the reader as its address (password menu 2 -> set address)
To run the connection test, click on "Contact Reader"
If you are able to ping and telnet (or otherwise communicate to) the handreader, but I cannot connect via the SchlageCommDiags utility: run it as 'admin': go to the SchlageCommDiags.exe icon, right-click on it, then select "run as..." and select "admin"
INFORMATION PROVIDED THROUGH THIS SITE IS PROVIDED TO YOU AS IS WITHOUT ANY EXPRESS REPRESENTATIONS OR WARRANTIES
OF ANY KIND, AND WE MAKE NO REPRESENTATION OR WARRANTY THAT THIS SITE(OR ANY INFORMATION PROVIDED IN RESPONSE TO
YOUR INQUIRY), WILL BE ACCURATE, COMPLETE, OR ERROR-FREE.
YOU AGREE THAT YOU MUST EVALUATE ALL INFORMATION AND RESPONSES, AND THAT YOU BEAR ALL RISKS ASSOCIATED WITH, THE
USE OF THIS SITE, INCLUDING ANY RELIANCE ON THE ACCURACY,COMPLETENESS, OR USEFULNESS OF ANY INFORMATION OR MATERIALS
MADE AVAILABLE THROUGH THIS SITE.