How many Chexit devices can be operated from the PS914 power supply?

Following information determine number of the Chexit devices that were shipped prior to 8-24-2015 from the factory with solenoid driven can be hooked up to a single Von Duprin PS873 or PS914 power supply.

   1. Two Chexit devices per power supply in high traffic openings.

   2. Up to four Chexit devices per power supply in low traffic openings with proper guage and run wire.

   3.Make sure each Chexit device has a different rearm time setting. See installation instruction 911352

Up to four Chexit devices that were shipped after 8-24-2015 from the factory with motor driven can be hooked up to a single Von Duprin PS914 power supply with proper gauge and run wire.


DISCLAIMER:

INFORMATION PROVIDED THROUGH THIS SITE IS PROVIDED TO YOU AS IS WITHOUT ANY EXPRESS REPRESENTATIONS OR WARRANTIES OF ANY KIND, AND WE MAKE NO REPRESENTATION OR WARRANTY THAT THIS SITE(OR ANY INFORMATION PROVIDED IN RESPONSE TO YOUR INQUIRY), WILL BE ACCURATE, COMPLETE, OR ERROR-FREE.

YOU AGREE THAT YOU MUST EVALUATE ALL INFORMATION AND RESPONSES, AND THAT YOU BEAR ALL RISKS ASSOCIATED WITH, THE USE OF THIS SITE, INCLUDING ANY RELIANCE ON THE ACCURACY,COMPLETENESS, OR USEFULNESS OF ANY INFORMATION OR MATERIALS MADE AVAILABLE THROUGH THIS SITE.