How do I couple a Hand Held Device to a PIM400

Remove the PIM400/401 cover. Connect the HHD to the PIM using the HH-USB cable. The PIM400/401 will be displayed on the HHD screen. On the HHD, select Device Options, On the PIM400/401, press and hold the LINK 1 button. Then press the LINK 2 button three times. On the HHD, select Couple HHD to Device. When Coupling is successful, a message will be displayed on the HHD screen.

You can also follow the proper procedure by linking to the Schlage Utility Software User Guide document on page 19 Couple HHD to PIM.

If the PIM400 has already been coupled with a HHD, the Coupling process will be disabled and the PIM400 will no longer go into its Coupling Mode.  You must RESET the PIM400 in order to allow (re-enable) coupling of the PIM400.


DISCLAIMER:

INFORMATION PROVIDED THROUGH THIS SITE IS PROVIDED TO YOU AS IS WITHOUT ANY EXPRESS REPRESENTATIONS OR WARRANTIES OF ANY KIND, AND WE MAKE NO REPRESENTATION OR WARRANTY THAT THIS SITE(OR ANY INFORMATION PROVIDED IN RESPONSE TO YOUR INQUIRY), WILL BE ACCURATE, COMPLETE, OR ERROR-FREE.

YOU AGREE THAT YOU MUST EVALUATE ALL INFORMATION AND RESPONSES, AND THAT YOU BEAR ALL RISKS ASSOCIATED WITH, THE USE OF THIS SITE, INCLUDING ANY RELIANCE ON THE ACCURACY,COMPLETENESS, OR USEFULNESS OF ANY INFORMATION OR MATERIALS MADE AVAILABLE THROUGH THIS SITE.

Other users ask