HandKey F-Series Ethernet EN-100 or EN-200 Network Requirements

HandKey F-Series Ethernet EN-100 or EN-200 Network Requirements

Ethernet Minimum Requirements
- A TCP/IP network
- CAT 5 cable or better
- 10baseT
- Static IP address, gateway and subnet addresses (if needed)
- TCP Port 3001 must be opened

Have the system administrator set Port 3001 to allow access on all switches and routers between the EN-100/200 and host program.

The EN-100/200 does not support DHCP; therefore a static IP address is required and must be programmed into the reader before the adapter will communicate with the network.


Full EN-100/200 Field Installable Ethernet Instructions found at:

http://us.allegion.com/IRSTDocuments1/70200-0014_J_Ethernet%20Upgrade.pdf