Can you convert the Glynn-Johnson Overhead units from Stop to Holder function, or from Holder to Stop function?

Yes, it is possible to convert the Glynn-Johnson Overhead units from Stop to Holder function, or from Holder to Stop function.  Note that fire-rated doors may not be held open with overhead holders.


70/79 Series: Parts are needed.

To convert from a holder to a stop, a stop washer is added and the hold open hook is removed.

To convert from a stop to a holder, a stop washer is removed and the hold open hook is added.

90 Series: A conversion kit is needed.  Conversion instructions can be found here.

100 Series: A conversion kit is needed.  Conversion instructions can be found here.

410 and 450 Series (400 Series): A conversion kit is needed.  Conversion instructions can be found here.