Can the 6111 electric strike be used with Falcon 25R?

The Falcon 25R rim device can be used with 6111 electric strike on single or double doors.

Additional Information:

  • The Von Duprin 4854/9854 mullion is required when using 25R with 6111 electric strike on double door application.
  • Only one 6111 electric strike can be installed on one side of the 4854/9854 mullion.
  • The 6111 has the same 13/16" projection as a 299 strike, therefore the same location shown in the Falcon (F)25-R template when using a 299 strike should be used.


For the backset see the Falcon (F)25-R template; T-1201 for Metal Door, W-1201 for Wood Door.
For Single Doors, the distance from the surface of the raised stop to the Centerline of the device is 2 1/4"
For Double Doors using the 4854 or 9854 mullion, the dimension from the center of the mullion to the Centerline of the device is 3-1/4".



DISCLAIMER:

INFORMATION PROVIDED THROUGH THIS SITE IS PROVIDED TO YOU AS IS WITHOUT ANY EXPRESS REPRESENTATIONS OR WARRANTIES OF ANY KIND, AND WE MAKE NO REPRESENTATION OR WARRANTY THAT THIS SITE(OR ANY INFORMATION PROVIDED IN RESPONSE TO YOUR INQUIRY), WILL BE ACCURATE, COMPLETE, OR ERROR-FREE.